~........................................................................ | OUTER FERRULE PART NUMBER | TOOL | .......................................................................... | ALL | CRIMP TOOL MS22520/5-01 | | | | | BACS13S261CNP | TOOL DIE MS22520/5-19 | | BACS13S312CNP | TOOL DIE MS22520/5-39 | | BACS13S327CNP | TOOL DIE MS22520/5-37 | 2..................................….....................................1
C. Consumable Materials
(1)
Braid, tubular, silver-plated copper,
0.25 inch, (or an equivalent); NEQ241636SP, New
England Electric Wire Corp., 365 Main St.,
Lisbon, New Hampshire 03585, USA
(2)
Tape, red rubber, self-bonding - Moxness
620-3/4, Moxness Products Inc., 1914 Indiana
St., Racine, WI 53405-3649, USA
(3)
Tape, Lacing - BMS13-54 Grade D, Type 3p; or
Gudebrod 718Z
(4)
Tape, electrical silicone - Scotch 62,
Minnesota Mining and Mfg. Co., 6801 River Place
Blvd, Austin, TX 94023, USA
(5)
Tape, electrical silicone - Scotch 92,
Minnesota Mining and Mfg. Co., 6801 River Place
Blvd, Austin, TX 94023, USA
(6)
Lockwire - MS20995N20
(7)
Wire splices (use the splices that follow as
necessary)
(a) FOR STANDARD WIRES;
BACT12C-20 (nickel plated copper)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
71-50-00
ALL ú ú N01 Page 802 ú Feb 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
(b)
FOR ALUMEL THERMOCOUPLE WIRES; 1-322325-0 (Alumel); AMPS Inc., 2800 Fulling Mill, P.O. Box 3608, Harrisburg, PA 17105, USA
(c)
FOR CHROMEL THERMOCOUPLE WIRES; 1-322325-1 (Chromel); AMPS Inc., 2800 Fulling Mill, P.O. Box 3608, Harrisburg, PA 17105, USA
(8) Cable ferrules (use the ferrules shown in these
tables as necessary):
~.............................................................................. | INNER FERRULE | ................................................................................ | APPLICATION | PART NUMBER | ................................................................................ | Two 20 gauge wires | BACS13S156BNP | | Two 18 gauge wires | BACS13S205BNP | | Two 20 gauge wires | BACS13S205BNP | | Three 20 gauge wires | BACS13S205BNP | | Two 18 gauge wires | BACS13S219BNP | | Two 20 gauge wires | BACS13S219BNP | | Three 18 gauge wires | BACS13S219BNP | | Three 20 gauge wires | BACS13S219BNP | 2.....................................…........................................1
~.............................................................................. | OUTER FERRULE | ................................................................................ | APPLICATION | PART NUMBER | ................................................................................ | Two 20 gauge wires | BACS13S261CNP | | Two 18 gauge wires | BACS13S312CNP | | Two 20 gauge wires | BACS13S312CNP | | Three 20 gauge wires | BACS13S312CNP | | Two 18 gauge wires | BACS13S327CNP | | Two 20 gauge wires | BACS13S327CNP | | Three 18 gauge wires | BACS13S327CNP | | Three 20 gauge wires | BACS13S327CNP | 2.....................................…........................................1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
71-50-00
ALL ú ú N01 Page 803 ú Oct 10/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / PW4000 SERIES /747-400 / ENGINES/MAINTENANCE MANUAL ////////////////////////
(9) Replacement cable (Refer to the WDM wire
diagrams and a wire list to get the correct
replacement cable).
NOTE:____Use the same type of cable as the damaged cable. If the same type of cable is not available, use the alternate cable shown in Table 1. You must splice thermocouple circuits with chromel and alumel wire and splices as applicable. The wire type codes used in the wire list are identified in the Standard Wiring Practices Manual D6-54446.
D. References
(1)
AMM 24-22-00/201, Electrical Power - Control