• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-27 17:17来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 - Open voltage : 5 to 50VDC

 - Min. open circuit resistance : 0.1 Megohm

 - Current : 2 to 10mA


 F 『 EEFF : ALL E Page 178-33-00
 E E Aug 01/04 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Thrust Reverser-Component Location
 Figure 001

 F 『 EEFF : ALL E Page 278-33-00
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Deploy Switch
 Figure 002

 F 『 EEFF : ALL E Page 378-33-00
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Deploy Switch
 Figure 003

 F 『 EEFF : ALL E Page 478-33-00
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Thrust Reverser Deploy/Stow Switch
 Figure 004

 F 『 EEFF : ALL E Page 578-33-00
 E E Feb 01/98 E E ECES E E 56-5B E E E - Max. closed circuit resistance : 5 ohms Each switch will be connected to ECU via shielded wires.

 F  『
 E  C F M  E
 E  E

 

 (2) Operation Initially, lever (1) is held in a neutral position under spring (3) force. Lever (2) transmits lever (1) motion to a plate (5), which controls cells A and B together. The doors in the deploying sequence come into contact with the lever 1 which is caused to rotate, (the force exerted by the actuator being greater than the spring (3) force). At 95% of the deployed position, the switch is closed. The switches are connected in series so that only when all the switch contacts are closed, the ECU will receive the information "all doors deployed".
 B. Stow Door Switch
 (Ref. Fig. 004, 005, 006, 007)

 (1) General The stowed position of the doors is sensed by four thrust reverser single switches, one per door, located onto the forward frame rear side next to the latches. The switches are dual, i.e. they include 2 cells one dedicated to each channel of the ECU. Junction wires, connection section are bedded in grease to avoid friction wear. A screw enables lever position rigging. Cells are hermetically sealed and include a compensatory system enabling their use in over-pressure (up to 2 bars). The switches are connected to the ECU via the electrical junction box. All stow switches are connected in parallel. At 0.9% of blocker doors flush position , the cells are closed . Electrical characteristics :

 - Open voltage : 5 to 50VDC

 - Min. open circuit resistance : 0.1 Megohm

 - Current : 2 to 10mA

 - Max. closed circuit resistance : 5 ohms

 

 (2) Operation Initially under spring (2) force, the lever (3) (linked in rotation with the lever (1)) holds the two cells (5) by the plate (4) and screw (6), in position (circuit 1 open, circuit 2 closed). When the door during its stowing sequence comes to 1.1% of its flush position, a spigot fixed onto the door makes contact with the lever (1) causing it to rotate (the force exerted by actuator being greater than the spring force). Lever (1) makes lever (3) rotate. At 0.9% of flush position, lever (3) position is such that the contacts are : circuit 1 closed, circuit 2 open.


 F 『 EEFF : ALL E Page 678-33-00
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Stow Switch
 Figure 005

 F 『 EEFF : ALL E Page 778-33-00
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Stow Switch
 Figure 006

 F 『 EEFF : ALL E Page 878-33-00
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Stow Switch Wiring
 Figure 007

 F 『 EEFF : ALL E Page 978-33-00
 E E Feb 01/98 E E ECES E

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


 The ECU receives the information one "stowed door". The contacts are
 connected in parallel.
 The signal combination and their complements enable to give the
 following information :

 - all the doors are stowed

 - 1, 2 or 3 unstowed doors

 - none stowed door.


 C. Latch (Ref. Fig. 008, 009)
 (1) General There are four latches, one per blocker door. The latches hold the doors in the stowed position and are located beside the actuators on the thrust reverser forward frame. The latches are connected in series. They are hydraulically supplied by the HCU (Hydraulic Control Unit). One latch includes :

 - a hook maintained in the unlocked position by two springs

 - a lever enabling under the action of two springs to maintain the hook in its locked position

 - a hydraulic actuator
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EXHAUST 2(89)