5. Close-up
________
Subtask 78-32-11-080-050
A. Remove the safety sleeve (HIX 3005) from the blocker door actuator (Ref. TASK 78-32-41-080-001).
Subtask 78-32-11-980-051
B. Move the Blocker Doors
CAUTION : BLOCKER DOOR LATCH MUST BE OPENED WHEN YOU CLOSE THE BLOCKER
_______
DOOR OR DAMAGE CAN OCCUR.
(1) Move the blocker doors to the closed position manually (Ref. TASK 78-32-41-860-002)
Subtask 78-32-11-410-053
C. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the thrust reverser doors (Ref. TASK 78-36-00-410-040): FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR
Subtask 78-32-11-440-051
D. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041).
Subtask 78-32-11-410-054
E. Close Access
(1) Close the fan cowl doors (Ref. TASK 71-13-00-410-040):
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(2) Remove the access platform(s).
(3) Remove the warning notice(s).
F 『 EEFF : ALL E Page 61678-32-11
E E Feb 01/98 E E ECES E TASK 78-32-11-220-040
F 『
E C F M E
E E
E 56-5B E
E E
Detailed Visual Inspection of the Inner Barrel Heatshield and Fire Protective Coating
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific warning notice
No specific access platform 1 m (3 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors 71-13-00-410-040 Closing of the Fan Cowl Doors 78-30-00-081-041 Make the Thrust Reverser Serviceable after
Maintenance 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance 78-36-00-010-040 Opening of the Thrust Reverser Doors 78-36-00-410-040 Closing of the Thrust Reverser Doors
3. Job Set-up
__________ Subtask 78-32-11-941-054
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
F 『 EEFF : ALL E Page 61778-32-11
E E Feb 01/98 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
Subtask 78-32-11-010-054
B. Get Access
(1) Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(2) Put the access platform in position.
Subtask 78-32-11-040-052
C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041).
Subtask 78-32-11-010-055
D. Open the thrust reverser doors (Ref. TASK 78-36-00-010-040):
FOR 1000EM1
451AL, 452AR
FOR 1000EM2
461AL, 462AR
F 『 EEFF : ALL E Page 61878-32-11
E E Feb 01/98 E E ECES E 4. Procedure
F 『
E C F M E
E E
E 56-5B E
E E
_________
Subtask 78-32-11-220-050
A. Do a Visual Inspection of the Inner Barrel Heatshield and Fire Protective Coating as follows
NOTE : If required, use a flashlight for hard to see places.
____
-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
1. Examine the inner barrel heatshield for :