_ interface between the C-Duct and the engine.
 (12) At the forward latches, put the locking brackets on the tension nuts and install the screws.

 (13) At the center latch, put the locking bracket on the tension nut and install the screw.

 (14) At the aft latch, put the locking bracket on the tension nut and install the screw.

 (15) TORQUE the screws to between 30 and 40 lbf.in (0.33 and 0.45 m.daN).

 (16) Close and lock the thrust reverser half door latches (four locations).


 5. Close-up
________
 Subtask 78-36-41-440-053

 A. Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041)
 F 『 EEFF : ALL E Page 50378-36-41
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E F 『 E C F M E E E E 56-5B E Subtask 78-36-41-410-056

 

 Thrust Reverser Half Door Latches
 Figure 501/TASK 78-36-41-991-302- 12 (SHEET 1)
 F EEFF :  ALL  『E 78-36-41 Page 504 
E  E  Feb 01/98
 E  E
 ECES  E

 


 Thrust Reverser Half Door Latches
 Figure 501/TASK 78-36-41-991-302- 22 (SHEET 2)
 F EEFF :  ALL  『E 78-36-41 Page 505 
E  E  Feb 01/98
 E  E
 ECES  E


 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


 B. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.

 (2) Close the fan cowl doors (Ref. TASK 71-13-00-410-040)
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR


 (3) Remove the warning notice(s).


 F 『 EEFF : ALL E Page 50678-36-41
 E E Feb 01/98 E E ECES E

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


 TASK 78-36-41-820-043 Inspection of the Thrust Reverser Half Door Latches
 1. Reason for the Job

__________________
 Self Explanatory


 2. Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific push gage: range 0 to 23 daN (0 to 50 lbf) No specific warning notice
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors 71-13-00-410-040 Closing of the Fan Cowl Doors 78-30-00-081-041 Make the Thrust Reverser Serviceable after
 Maintenance 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
 Maintenance 78-36-41-820-042 Adjustment of the Thrust Reverser Half Door Latches 78-36-41-991-304 Fig. 502
 3. Job Set-up
__________ Subtask 78-36-41-941-054
 A. Safety Precautions
 (1) On the center pedestal, on the ENG panel 115VU:

 (a) Put a warning notice to tell persons not to start the engine.

 (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.


 F 『 EEFF : ALL E Page 50778-36-41
 E E Feb 01/98 E E ECES E

 F 『
 E C F M E
 E E
 E 56-5B E
 E E
 (3) On the overhead maintenance panel 50VU:

 (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.

 (b) Put a warning notice to tell persons not to energize the FADEC 1(2).


 Subtask 78-36-41-010-057
 B. Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR.

 Subtask 78-36-41-040-054
 C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041).
 4. Procedure
_________
 (Ref. Fig. 502/TASK 78-36-41-991-304)
 Subtask 78-36-41-820-052
 A. Inspection of the thrust reverser half door latches
 NOTE : This procedure should only be used to check the thrust reverser
____ half door latch adjustment and not used to adjust the half door latches.
 (1) Release the forward latch. The other three latches are to stay locked.

 (2) Place the push gage: range 0 to 23 daN (0 to 50 lbf) on the tip of the latch handle.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EXHAUST 2(106)