F 『
E C F M E
E E
E 56-5B E
E E
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
Subtask 78-36-41-010-050
B. Open the fan cowl doors: (Ref. TASK 71-13-00-010-040)
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
Subtask 78-36-41-040-050
C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041) Subtask 78-36-41-010-051
D. Open the right thrust reverser door: (Ref. TASK 78-36-00-010-040) FOR 1000EM1 452AR FOR 1000EM2 462AR
4. Procedure
_________ (Ref. Fig. 401/TASK 78-36-41-991-300) Subtask 78-36-41-020-050
A. Removal of the Thrust Half Door Latches:
(1) Removal of the Forward Half Door Latches
(a) Remove and discard the cotter pin (5).
(b) Remove the nut (10) and the bolt (20).
(c) Remove the latches (15) from the thrust reverser half door.
F 『 EEFF : ALL E Page 40278-36-41
E E Feb 01/98 E E ECES E E 56-5B E E E (2) Removal of the Middle Half Door Latch
F 『
E C F M E
E E
(a) Remove and discard the cotter pin (5).
(b) Remove the nut (10) and the bolt (30).
(c) Remove the latch (25) from the thrust reverser half door.
(3) Removal of the Aft Half Door Latch
(a) Remove and discard the cotter pin (5).
(b) Remove the nut (10) and the bolt (35).
(c) Remove the latch (25) from the thrust reverser half door.
F 『 EEFF : ALL E Page 40378-36-41
E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E F 『 E C F M E E E E 56-5B E
Thrust Reverser Half Door Latches
Figure 401/TASK 78-36-41-991-300- 12 (SHEET 1)
F EEFF : ALL 『E 78-36-41 Page 404
E E Feb 01/98
E E
ECES E
Thrust Reverser Half Door Latches
Figure 401/TASK 78-36-41-991-300- 22 (SHEET 2)
F EEFF : ALL 『E 78-36-41 Page 405
E E Feb 01/98
E E
ECES E
F 『
E C F M E
E E
E 56-5B E
E E
TASK 78-36-41-400-043
Installation of the Thrust Reverser Half Door Latches
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific warning notice
B. Expendable Parts
-------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
-------------------------------------------------------------------------------
R 05 cotter pin 78-36-41 01B-020 R 05 cotter pin 78-36-41 01B-090
C. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
71-13-00-410-040 Closing of the Fan Cowl Doors
78-30-00-081-041 Make the Thrust Reverser Serviceable after
Maintenance
78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance
78-36-00-010-040 Opening of the Thrust Reverser Doors
78-36-00-410-040 Closing of the Thrust Reverser Doors
78-36-41-991-300 Fig. 401
F 『 EEFF : ALL E Page 40678-36-41
E E Aug 01/03 E E ECES E 3. Job Set-up
F 『
E C F M E
E E
E 56-5B E
E E
__________
Subtask 78-36-41-860-050
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a warning notice is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a warning notice is in position to tell persons not to energize the FADEC 1(2). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM EXHAUST 2(100)