(2) Disconnect the lower head supply hose from the actuator and let the hydraulic fluid drain into the container.
(3) Remove the bolts and the nuts that attach the lower head shield to the forward frame.
(4) Disconnect the lower head supply hose from the lower head swivel joint.
(5) Remove the lower head supply hose from the forward frame.
(6) Put protective covers on the open connections.
F 『 EEFF : ALL E Page A49978-31-49
E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E
Lower Head Supply Hose
Figure 424/TASK 78-31-49-991-325
F 『 EEFF : ALL E Page B40078-31-49
E E Feb 01/98 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
TASK 78-31-49-400-008
Installation of the Lower Head Supply Hose
WARNING : WEAR A FACE SHIELD WHICH IS RESISTANT TO HIGH PRESSURE JETS WHEN YOU
_______
WORK ON PRESSURIZED SYSTEMS.
R WARNING : DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
_______ R - FLUSH IT AWAY WITH CLEAN WATER R - GET MEDICAL AID.
CAUTION : USE 2 WRENCHES TO REMOVE OR INSTALL THE TUBE COUPLING NUTS.
_______
ONE WRENCH TO HOLD THE UNION AND ONE TO LOOSEN OR TIGHTEN THE
COUPLING NUT. THIS WILL PREVENT DAMAGE TO THE HARDWARE.
CAUTION : MAKE SURE THERE IS NO UNWANTED MATERIAL IN THE PORTS AND ORIFICES OR
_______
DAMAGE CAN OCCUR.
CAUTION : YOU MUST INSTALL HYDRAULIC TUBES WITH HYDRAULIC FLUID AS LUBRICANT.
_______
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific warning notice
No specific access platform 1 m (3 ft. 3 in.)
No specific Torque Wrench : range 36.00 to 220.00 lbf.in
(0.40 to 2.60 m.daN)
No specific Torque Wrench : range 96.00 to 900.00 lbf.in
(1.00 to 10.00 m.daN)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. CP2245 *
finish paint EA4 blue 5991 (Ref. 70-30-00)
F 『 EEFF : ALL E Page B40178-31-49
E E May 01/05 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors 71-13-00-410-040 Closing of the Fan Cowl Doors 78-30-00-081-041 Make the Thrust Reverser Serviceable after
Maintenance 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance 78-30-00-710-040 Thrust Reverser Hydraulic System Bleed Procedure 78-31-49-991-325 Fig. 424
3. Job Set-up
__________
Subtask 78-31-49-860-103
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a warning notice is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a warning notice is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the access platform is in position.
Subtask 78-31-49-010-160
B. Make sure that the fan cowl doors are open: (Ref. TASK 71-13-00-010-040) FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
Subtask 78-31-49-040-148
C. Make sure that the thrust reverser is unserviceable (Ref. TASK 78-30-00-481-041).
F 『 EEFF : ALL E Page B40278-31-49
E E Feb 01/98 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
4. Procedure
_________
(Ref. Fig. 424/TASK 78-31-49-991-325)
Subtask 78-31-49-420-094
A. Installation of the Lower Head Supply Hose 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM EXHAUST 2(18)