1EFF : ALL 1 27-93-00Page 505 1 1 May 01/05R 1 1 1CES 1
5. Close-up________
Subtask 27-93-00-860-054
A. Put the aircraft back to its initial configuration.
R R (1) On the overhead panel 23VU: - push the FLT CTL/SEC 1 pushbutton switch (on this pushbutton switch, the OFF legend goes off).
R R (2) On the overhead panel 24VU: - push the FLT CTL/SEC 2 and FLT CTL/SEC 3 pushbutton switches (on these pushbutton switches, the OFF legend goes off).
(3) Depressurize the aircraft hydraulic systems (Ref. TASK 29-23-00-864-001) (Ref. TASK 29-24-00-864-001) (Ref. TASK 29-10-00-864-003).
(4) Do the EIS stop procedure (Ref. TASK 31-60-00-860-002).
(5) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
Subtask 27-93-00-410-050
B. Close Access
(1) Install the protective cover on the battery power center 105VU.
(2) Tighten the two screws.
(3) Close the access door 822.
(4) Remove the access platform(s).
TASK 27-93-00-710-002
Operational Test of the ELAC 2 STBY PWR SPLY Availability in case of loss of Blue Hydraulic Pressure (To be done before revenue flight landing gear down)
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002
24-41-00-862-002
29-10-00-863-003
29-10-00-864-003 29-23-00-863-001
29-23-00-864-001
29-24-00-863-001
R R R R 29-24-00-864-001 31-60-00-860-001 31-60-00-860-002 32-00-00-860-001 32-00-00-860-002
3. Job Set-up__________
Subtask 27-93-00-861-053
Energize the Aircraft Electrical Circuits from the External PowerDe-energize the Aircraft Electrical Circuits Supplied from the External PowerPressurize the Blue Hydraulic System with a Ground Power SupplyDepressurize the Blue Hydraulic SystemPressurize the Green Hydraulic System from the Yellow Hydraulic System through the PTU with the Electric PumpDepressurize the Green and Yellow Hydraulic Systems after Operation of the PTUPressurize the Yellow Hydraulic System with the Electric PumpDepressurize the Yellow Hydraulic SystemEIS Start ProcedureEIS Stop Procedure Flight Configuration Precautions with Electrical Power Ground Configuration after Flight Configuration with Electrical Power
A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
Subtask 27-93-00-865-053
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU L/G/LGCIU/SYS1/NORM 1GA C09 121VU HYDRAULIC/LGCIU/SYS1/GRND SPLY 52GA Q34 121VU FLIGHT CONTROLS/THS ACTR/MOT1 19CE1 Q16 121VU FLIGHT CONTROLS/ELAC2/NORM/SPLY 15CE2 R20
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵9(77)