A. Put the aircraft back to its initial configuration.
(1)
On the overhead panel 20VU, on the ADIRS CDU:
-set the 3 OFF/NAV/ATT selector switches to OFF.
(2)
De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
Subtask 27-96-00-410-053
B. Close Access
(1)
Install the protective cover on the battery power center 105VU.
(2)
Tighten the two screws.
(3)
Close the access door 822.
(4)
Remove the access platform(s).
1EFF : ALL 1 27-96-00Page 537 1 1 Aug 01/05R 1 1 1CES 1
TASK 27-96-00-710-018
R Operational Test of Logics Activating ELAC 1&2, & SEC 1 STBY PWR SPLY & Ability R of SEC 1&2 to Achieve Pitch CTL & Ability of Sidestick Priority Function
WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______
MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE.
1. Reason for the Job
__________________
Refer to the MPD TASK: 279000-05
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
No specific access platform 1.6 m (5 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 29-10-00-863-003 Pressurize the Blue Hydraulic System with a Ground
Power Supply 29-10-00-864-003 Depressurize the Blue Hydraulic System 29-23-00-863-001 Pressurize the Green Hydraulic System from the Yellow
Hydraulic System through the PTU with the Electric Pump 29-23-00-864-001 Depressurize the Green and Yellow Hydraulic Systems after Operation of the PTU 29-24-00-863-001 Pressurize the Yellow Hydraulic System with the
Electric Pump
29-24-00-864-001 Depressurize the Yellow Hydraulic System
31-60-00-860-001 EIS Start Procedure
31-60-00-860-002 EIS Stop Procedure
3. Job Set-up
__________ Subtask 27-96-00-860-050
A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
(2)
On the overhead panel 23VU:
-Make sure that the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches are pushed (on these pushbutton switches, the OFF and FAULT legends are off).
(3)
On the overhead panel 24VU:
-Make sure that the FLT CTL/ELAC 2, FLT CTL/SEC 2 and FLT CTL/SEC 3 pushbutton switches are pushed (on these pushbutton switches, the OFF and FAULT legends are off).
(4)
On the overhead panel 20VU, on the ADIRS CDU:
-set the 3 OFF/NAV/ATT selector switches to NAV.
(5)
Do the EIS start procedure (Ref. TASK 31-60-00-860-001).
(6)
On the center pedestal, on the ECAM control panel push:
-
the CLEAR key until all the warnings (if any) stop
-
the F/CTL key (on the lower ECAM display unit, the F/CTL page comes into view).
(7)
Make sure that Green and Yellow hydraulic systems are depressurized (Ref. TASK 29-23-00-864-001) (Ref. TASK 29-24-00-864-001).
(8) Pressurize the Blue hydraulic system (Ref. TASK 29-10-00-863-003). Subtask 27-96-00-010-064
B. Get Access
(1)
Put the access platform in position at the access door 822.
(2)
Open the access door 822.
(3)
On the battery power center 105VU:
-loosen the two screws and remove the protective cover.
1EFF : ALL 1 27-96-00Page 539 1 1 Aug 01/05R 1 1 1CES 1
Subtask 27-96-00-865-073
C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------
PANEL ------ DESIGNATION ------------------------------------------------------- IDENT. LOCATION------------------
49VU FLIGHT CONTROLS/ELAC1/NORM/SPLY 15CE1 B11
49VU FLIGHT CONTROLS/THS/ACTR/MOT2 19CE2 B09
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵9(126)