On the overhead panel 23VU:
-the FAULT legends of the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches go off.
 On the upper ECAM display unit, the ELAC 1 FAULT and SEC 1 FAULT warnings go out of view.
 On the lower ECAM display unit, the ELAC 1 and SEC 1 legends change to green.
On the overhead panel 24VU:
-the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch comes on.
 On the upper ECAM display unit, the ELAC 2 FAULT warning comes into view.
R 1EFF : 151-199, 1 27-96-00Page 552 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
On the lower ECAM display unit, the ELAC 2 legend changes to amber.
 6. Open the circuit breaker 19CE1.  On the overhead panel 24VU: - the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch goes off.
 On the upper ECAM display unit, the ELAC 2 FAULT warning go out of view.
 On the lower ECAM display unit, the ELAC 2 legend changes to green.
 After approximately 30 seconds:
 - On the lower ECAM display unit, the ELAC 2 legend changes to amber again.
 - On the upper ECAM display unit, the ELAC 2 FAULT warning comes into view.
 On the overhead panel 24VU, there is no FAULT legend on on the FLT CTL/ELAC 2 pushbutton switch.
 7. On the overhead panel 40VU: - push the YELLOW/ELEC PUMP pushbutton switch.  On the overhead panel 40VU:- the ON legend of the YELLOW/ELEC PUMPpushbutton switch comes on.
 8. On the panel 50VU: - release the BLUE PUMP OVRD pushbutton switch.  On the panel 50VU:- the ON legend of the BLUE PUMP OVRDpushbutton switch goes off.
 On the overhead panel 24VU: - the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch is off.
 On the upper ECAM display unit, the ELAC 2 FAULT warning goes out of view.
 On the lower ECAM display unit, the ELAC 2 legend changes to green.
 9. On the panel 50VU:  On the panel 50VU: 

R 1EFF : 151-199, 1 27-96-00Page 553 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-push the BLUE PUMP OVRD pushbutton switch.
10. On the overhead panel 40VU:
-release the YELLOW/ELEC PUMP pushbutton switch.
11.
 Close the circuit breakers 1GA and 52GA.

12.
 Open the circuit breakers 1GA and 52GA.

13.
 Close the circuit breakers 1GA and 52GA.

14.
 On the overhead panel 23VU:


-the ON legend of the BLUE PUMP OVRDpushbutton switch comes on.
 On the upper ECAM display unit, the ELAC 2 FAULT warning comes into view.
 On the lower ECAM display unit, the ELAC 2 legend changes to amber.
 On the overhead panel 24VU, there is no FAULT legend on on the FLT CTL/ELAC 2 pushbutton switch.
On the overhead panel 40VU:
-the 0N legend of the YELLOW/ELEC PUMPpushbutton switch goes off.
On the lower ECAM display unit, theELAC 2 legend changes to green.
 On the upper ECAM display unit, the ELAC 2 FAULT warning goes out of view.
On the lower ECAM display unit, theELAC 2 legend is green.
 On the upper ECAM display unit, there is no ELAC 2 FAULT warning.
 On the overhead panel 24VU, FAULT legend on the FLT CTL/ELAC 2 pushbutton switch is off.
On the lower ECAM display unit, theELAC 2 legend is green.
 On the upper ECAM display unit, there is no ELAC 2 FAULT warning.
 On the overhead panel 24VU, FAULT legend on the FLT CTL/ELAC 2 pushbutton switch is off.
On the overhead panel 23VU:
R 1EFF : 151-199, 1 27-96-00Page 554 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- release the FLT CTL/ELAC 1 pushbutton switch.  - the OFF legend of the FLT CTL/ELAC 1pushbutton switch comes on.
 On the lower ECAM display unit: - the ELAC 1 legend changes to amber - the ELAC 2 legend remains green.
 15. On the overhead panel 23VU: - release the FLT CTL/SEC 1 pushbutton switch.  On the overhead panel 23VU:- the OFF legend of the FLT CTL/SEC 1pushbutton switch comes on.
 On the overhead panel 24VU: - the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch comes on.
 On the lower ECAM display unit: - the SEC 1 legend changes to amber. - the ELAC 2 legend changes to amber.
 On the upper ECAM display unit, the ELAC 2 FAULT warning comes into view.
 16. On the overhead panel 23VU: - push the FLT CTL/ELAC 1 pushbutton switch.  On the overhead panel 23VU:- the OFF legend of the FLT CTL/ELAC 1pushbutton switch goes off.
 