After approximately five seconds, the pitch-trim control wheel goes back automatically to the O position.
On the lower ECAM display unit, on the F/CTL page:
-the PITCH TRIM indicator shows 0 DEG plus or minus 0.3 .
After approximately five seconds, the pitch-trim control wheel goes back automatically to the O position.
On the lower ECAM display unit, on the F/CTL page:
-
the PITCH TRIM indicator shows 0 DEG plus or minus 0.3 .
On the overhead panel 23VU:
-
the OFF legends of the FLT CTL/ELAC 1 and FLT CTL/SEC1 pushbutton switches go off.
On the overhead panel 24VU:
-
the OFF legend of the FLT CTL/ELAC 2 pushbutton switch goes off.
On the lower ECAM display unit, the B indication becomes amber.
R 1EFF : 001-049, 051-099, 101-105, 201-203, 1 27-96-00Page 581 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R 46. Pressurize the Blue hydraulic
R system (Ref. TASK 29-10-00-863-
R 003).
R 47. On the overhead panel 23VU:
R - release the FLT CTL/ELAC 1
R pushbutton switch.
R 48. On the overhead panel 24VU:
R - release the FLT CTL/ELAC 2 and
R FLT CTL/SEC 2 pushbutton
R switches.
R 49. On the CAPT side:
R - give the orders below one
R after the other and keep the
R side stick in each position
R for 3 seconds :
R - full nose up
R - full nose down
R - full right turn
R - full left turn
R - move the side stick back to
R the neutral position.
R 50. On the F/O side:
R - give the orders below one
R after the other and keep the
R side stick in each position
R for 3 seconds :
R - full nose up
R - full nose down
R - full right turn
R - full left turn
R - move the side stick back to
R the neutral position.
R 51. Set the pitch-trim control wheel
R to the 10 UP position.
R 52. On the overhead panel 23VU:
R - release and push again the FLT
R CTL/SEC 1 pushbutton switch.
On the lower ECAM display unit, the B indication becomes green.
On the overhead panel 23VU:
-
the OFF legend of the FLT CTL/ELAC 1 pushbutton switch comes on.
On the overhead panel 24VU:
-
the OFF legends of the FLT CTL/ELAC 2 and FLT CTL/SEC 2 pushbutton switches come on.
On the lower ECAM display unit, on the F/CTL page:
-
the indexes which show the position of the elevators and spoilers 2, 3 and 4 move in relation to the side stick orders.
On the lower ECAM display unit, on the F/CTL page:
-the indexes which show the position of the elevators and spoilers 2, 3 and 4 move in relation to the side stick orders.
After approximately five seconds, the pitch-trim control wheel goes back automatically to the O position.
R 1EFF : 001-049, 051-099, 101-105, 201-203, 1 27-96-00Page 582 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R
R
R
R
R 53. Set the pitch-trim control wheel
R to the 3 DN position.
R 54. On the overhead panel 23VU:
R - release and push again the FLT
R CTL/SEC 1 pushbutton switch.
R
R
R
R
R 55. Open the circuit breakers 15CE1
R and 15CE2.
R
R 56. On the CAPT or F/O side:
R - give the orders below one
R after the other:
R - full nose up
R - full nose down
R - full right turn
R - full left turn
R - move the side stick back to
R the neutral position.
R 57. On the overhead panel 23VU:
中国航空网 www.aero.cn