• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-22 06:40来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  - full left turn 
R  - move the side stick back to 
R  the neutral position. 
R  63. Close the circuit breakers 15CE1 
R  and 15CE2. 

**ON A/C ALL
 5. Close-up________
 Subtask 27-96-00-865-077

On the lower ECAM display unit, on the F/CTL page:
-
the indexes which show the position of the elevators and spoilers 2, 3 and 4 move in relation to the side stick orders.

On the overhead panel 23VU:

-
the OFF legend of the FLT CTL/SEC 1 comes on.

On the overhead panel 24VU:

-
the OFF legend of the FLT CTL/SEC 2 goes off.

On the lower ECAM display unit, on the F/CTL page:

-
the indexes which show the position of the elevators and spoilers N. 2 and 5 move in relation to the side stick orders.

On the upper ECAM display unit:

-
the F/CTL ELAC 1 FAULT and F/CTL ELAC 2 FAULT messages go out of view.


 A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1DA1, 1DA2, 2DA1, 2DA2, 2DA3, 3DA1, 3DA2, 3DA3, 4DA1, 4DA2, 4DA3, 4DG1, 4DG2, 5DA1, 5DA2, 5DA3, 5DG1, 5DG2 Subtask 27-96-00-860-084


 B. Put the aircraft back to the initial configuration
 (1)
 Depressurize the aircraft hydraulic systems (Ref. TASK 29-23-00-864-001) (Ref. TASK 29-24-00-864-001) (Ref. TASK 29-10-00-864-003).

 (2)
 on the overhead panel 23VU:

 -push the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches (on these pushbutton switches, the OFF legends go off).

 (3)
 On the overhead panel 24VU:

 -push the FLT CTL/ELAC 2 pushbutton switch (on this pushbutton switch, the OFF legend goes off).

 (4)
 On the overhead panel 20VU, on the ADIRS CDU:

 -set the 3 OFF/NAV/ATT selector switches to OFF.

 (5)
 Do the EIS stop procedure (Ref. TASK 31-60-00-860-002).

 (6)
 De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).


 (7) Remove the warning notice. Subtask 27-96-00-410-065
 C. Close Access
 (1)
 Install the protective cover on the battery power center 105VU.

 (2)
 Tighten the two screws.

 (3)
 Close the access door 822.

 (4)
 Remove the access platform(s).


 1EFF : ALL 1 27-96-00Page A507 1 1 Aug 01/05R 1 1 1CES 1


 TASK 27-96-00-710-020
 Operational Test of the Side Stick Assembly (Activation for the BITE Test)
 WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______ YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
 WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______ START A TASK ON OR NEAR:
 -
THE FLIGHT CONTROLS

 -
THE FLIGHT CONTROL SURFACES

 -
THE LANDING GEAR AND THE RELATED DOORS


 -COMPONENTS THAT MOVE.
 1. Reason for the Job
__________________
 This test is applicable only during a trouble-shooting action.
 This test activates a BITE test on the EFCS in a special configuration
 defined by the trouble-shooting procedure.

 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 1.6 m (5 ft. 3 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 29-10-00-863-003 Pressurize the Blue Hydraulic System with a Ground
 Power Supply 29-10-00-864-003 Depressurize the Blue Hydraulic System 29-23-00-863-001 Pressurize the Green Hydraulic System from the Yellow
 Hydraulic System through the PTU with the Electric Pump
 1EFF : ALL 1 27-96-00Page A508 1 1 Aug 01/05R 1 1 1CES 1


 -------------------------------------------------------------------------------
REFERENCE DESIGNATION -------------------------------------------------------------------------------
29-23-00-864-001  Depressurize the Green and Yellow Hydraulic Systems after Operation of the PTU
 29-24-00-863-001  Pressurize the Yellow Hydraulic System with the Electric Pump
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵9(157)