-------------------------------------------------------------------------------49VU ANTI ICE/PROBES/AOA/1 4DA1 D04 49VU ANTI ICE/PROBES/PHC/1 2DA1 D03 49VU ANTI ICE/PROBES/PITOT/1 3DA1 D02 122VU ANTI ICE/WINDOWS/R 4DG2 W14 122VU ANTI ICE/WHC/2 5DG2 W13 122VU ANTI ICE/WINDOWS/L 4DG1 X14 122VU ANTI ICE/WHC/1 5DG1 X13 122VU ANTI ICE/PROBES/PHC/3 2DA3 Y16 122VU ANTI ICE/PROBES/2/TAT 1DA2 Y15 122VU ANTI ICE/PROBES/2/PITOT 3DA2 Y14 122VU ANTI ICE/PROBES/2/AOA 4DA2 Y13 122VU ANTI ICE/PROBES/2/PHC 2DA2 Y12 122VU ANTI ICE/PROBES/2/STATIC 5DA2 Y11 122VU ANTI ICE/PROBES/3/PITOT 3DA3 Z16 122VU ANTI ICE/PROBES/3/AOA 4DA3 Z15 122VU ANTI ICE/PROBES/3/STATIC 5DA3 Z14 122VU ANTI ICE/PROBES/1/STATIC 5DA1 Z13 122VU ANTI ICE/PROBES/1/TAT 1DA1 Z12
1EFF : ALL 1 27-96-00Page 540 1 1 Aug 01/05R 1 1 1CES 1
4. Procedure
_________ **ON A/C 001-049, 051-099, 101-105, 201-203,
Subtask 27-96-00-710-081
A. Operational Test of the Logics that activates the ELAC 1 & 2 and SEC1 STBY PWR SPLY and Ability of the ELAC 1 and SEC 1 & 2 to Achieve Pitch Control
NOTE : During the test, ignore the MASTER CAUT legend and single shime.
____
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. Open the circuit breakers 15CE1 and 21CE1. On the overhead panel 23VU:- the FAULT legends of the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches are off.
2. On the panel 50VU: - release the BLUE PUMP OVRD pushbutton switch. On the panel 50VU:- the ON legend of the BLUE PUMP OVRDpushbutton switch goes off.
On the overhead panel 23VU: - the FAULT legends of the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches are off.
After approximately 30 seconds the FAULT legends come on.
On the upper ECAM display unit, the ELAC 1 FAULT and SEC 1 FAULT warnings come into view.
On the lower ECAM display unit, the ELAC 1 and SEC 1 legends change to amber.
3. On the panel 50VU: - push the BLUE PUMP OVRD pushbutton switch. On the overhead panel 50VU:- the ON legend of the BLUE PUMP OVRDpushbutton switch comes on.
1EFF : ALL 1 27-96-00Page 541 1 1 Aug 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
4.
Close the circuit breakers 15CE1 and 21CE1.
5.
Open the circuit breakers 52GA (if installed), 1GA and 15CE2.
NOTE : Ignore the warning related
____
to the other systems
6. Open the circuit breaker 19CE1.
The above mentioned warnings are still shown.
On the overhead panel 23VU:
-the FAULT legends of the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches go off.
On the upper ECAM display unit, the ELAC 1 FAULT and SEC 1 FAULT warnings go out of view.
On the lower ECAM display unit, the ELAC 1 and SEC 1 legends change to green.
On the overhead panel 24VU:
-the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch comes on.
On the upper ECAM display unit, the ELAC 2 FAULT warning comes into view.
On the lower ECAM display unit, the ELAC 2 legend changes to amber.
On the overhead panel 24VU:
-the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch goes off.
On the upper ECAM display unit, the ELAC 2 FAULT warning go out of view.
On the lower ECAM display unit, the ELAC 2 legend changes to green.
After approximately 30 seconds:
-On the lower ECAM display unit, the ELAC 2 legend changes to amber again.
R 1EFF : 001-049, 051-099, 101-105, 201-203, 1 27-96-00Page 542 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------