On the overhead panel 23VU:
-the FAULT legends of the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches are off.
After approximately 30 seconds the FAULT legends come on.
On the upper ECAM display unit, the ELAC 1 FAULT and SEC 1 FAULT warnings come into view.
On the lower ECAM display unit, the ELAC 1 and SEC 1 legends change to amber.
On the overhead panel 50VU:
-the ON legend of the BLUE PUMP OVRD pushbutton switch comes on.
The above mentioned warnings are still shown.
On the overhead panel 23VU:
-the FAULT legends of the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches go off.
On the upper ECAM display unit, the ELAC 1 FAULT and SEC 1 FAULT warnings go out of view.
On the lower ECAM display unit, the ELAC 1 and SEC 1 legends change to green.
On the overhead panel 24VU:
-the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch comes on.
R 1EFF : 151-199, 301-399, 401-499, 1 27-96-00Page 596 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning comes into view.
R On the lower ECAM display unit, the
R ELAC 2 legend changes to amber.
R 6. Open the circuit breaker 19CE1. On the overhead panel 24VU:
R - the FAULT legend of the FLT CTL/ELAC
R 2 pushbutton switch goes off.
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning go out of view.
R On the lower ECAM display unit, the
R ELAC 2 legend changes to green.
R After approximately 30 seconds:
R - On the lower ECAM display unit, the
R ELAC 2 legend changes to amber again.
R - On the upper ECAM display unit, the
R ELAC 2 FAULT warning comes into view.
R On the overhead panel 24VU, there is no
R FAULT legend on on the FLT CTL/ELAC 2
R pushbutton switch.
R 7. On the overhead panel 40VU: On the overhead panel 40VU:
R - push the YELLOW/ELEC PUMP - the ON legend of the YELLOW/ELEC PUMP
R pushbutton switch. pushbutton switch comes on.
R 8. On the panel 50VU: On the panel 50VU:
R - release the BLUE PUMP OVRD - the ON legend of the BLUE PUMP OVRD
R pushbutton switch. pushbutton switch goes off.
R On the overhead panel 24VU:
R - the FAULT legend of the FLT CTL/ELAC
R 2 pushbutton switch is off.
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning goes out of view.
R 1EFF : 151-199, 301-399, 401-499, 1 27-96-00Page 597 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R On the lower ECAM display unit, the
R ELAC 2 legend changes to green.
R 9. On the panel 50VU: On the panel 50VU:
R - push the BLUE PUMP OVRD - the ON legend of the BLUE PUMP OVRD
R pushbutton switch. pushbutton switch comes on.
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning comes into view.
R On the lower ECAM display unit, the
R ELAC 2 legend changes to amber.
R On the overhead panel 24VU, there is no
R FAULT legend on on the FLT CTL/ELAC 2
R pushbutton switch.
R 10. On the overhead panel 40VU: On the overhead panel 40VU:
R - release the YELLOW/ELEC PUMP - the 0N legend of the YELLOW/ELEC PUMP
R pushbutton switch. pushbutton switch goes off.
R 11. Close the circuit breakers 1GA On the lower ECAM display unit, the
R and 52GA. ELAC 2 legend changes to green.
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning goes out of view.
中国航空网 www.aero.cn