-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning go out of view.
R On the lower ECAM display unit, the
R ELAC 2 legend changes to green.
R After approximately 30 seconds:
R - On the lower ECAM display unit, the
R ELAC 2 legend changes to amber again.
R - On the upper ECAM display unit, the
R ELAC 2 FAULT warning comes into view.
R On the overhead panel 24VU, there is no
R FAULT legend on on the FLT CTL/ELAC 2
R pushbutton switch.
R 7. On the overhead panel 40VU: On the overhead panel 40VU:
R - push the YELLOW/ELEC PUMP - the ON legend of the YELLOW/ELEC PUMP
R pushbutton switch. pushbutton switch comes on.
R 8. On the panel 50VU: On the panel 50VU:
R - release the BLUE PUMP OVRD - the ON legend of the BLUE PUMP OVRD
R pushbutton switch. pushbutton switch goes off.
R On the overhead panel 24VU:
R - the FAULT legend of the FLT CTL/ELAC
R 2 pushbutton switch is off.
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning goes out of view.
R On the lower ECAM display unit, the
R ELAC 2 legend changes to green.
R 9. On the panel 50VU: On the panel 50VU:
R - push the BLUE PUMP OVRD - the ON legend of the BLUE PUMP OVRD
R pushbutton switch. pushbutton switch comes on.
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning comes into view.
R 1EFF : 106-149, 204-299, 1 27-96-00Page 586 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R On the lower ECAM display unit, the
R ELAC 2 legend changes to amber.
R On the overhead panel 24VU, there is no
R FAULT legend on on the FLT CTL/ELAC 2
R pushbutton switch.
R 10. On the overhead panel 40VU: On the overhead panel 40VU:
R - release the YELLOW/ELEC PUMP - the 0N legend of the YELLOW/ELEC PUMP
R pushbutton switch. pushbutton switch goes off.
R 11. Close the circuit breakers 1GA On the lower ECAM display unit, the
R and 52GA. ELAC 2 legend changes to green.
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning goes out of view.
R 12. Open the circuit breakers 1GA On the lower ECAM display unit, the
R and 52GA. ELAC 2 legend is green.
R On the upper ECAM display unit, there
R is no ELAC 2 FAULT warning.
R On the overhead panel 24VU, FAULT
R legend on the FLT CTL/ELAC 2 pushbutton
R switch is off.
R 13. Close the circuit breakers 1GA On the lower ECAM display unit, the
R and 52GA. ELAC 2 legend is green.
R On the upper ECAM display unit, there
R is no ELAC 2 FAULT warning.
R On the overhead panel 24VU, FAULT
R legend on the FLT CTL/ELAC 2 pushbutton
R switch is off.
R 14. On the overhead panel 23VU: On the overhead panel 23VU:
R - release the FLT CTL/ELAC 1 - the OFF legend of the FLT CTL/ELAC 1
R pushbutton switch. pushbutton switch comes on.
R On the lower ECAM display unit:
R - the ELAC 1 legend changes to amber
R - the ELAC 2 legend remains green.
R 1EFF : 106-149, 204-299, 1 27-96-00Page 587 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R R R 15. On the overhead panel 23VU: - release the FLT CTL/SEC 1 pushbutton switch.