the OFF legend of the FLT CTL/SEC 2 goes off.
On the lower ECAM display unit, on the F/CTL page:
-
the indexes which show the position of the elevators and spoilers N. 2 and 5 move in relation to the side stick orders.
On the upper ECAM display unit:
-
the F/CTL ELAC 1 FAULT and F/CTL ELAC 2 FAULT messages go out of view.
R **ON A/C 001-049, 051-099, 101-105, 201-203,
R Post SB 27-1113 For A/C 001-049,051-099,101-105,201-203,
R Post SB 31-1115 For A/C 001-049,051-099,101-105,201-203,
R Subtask 27-96-00-710-081-C
R A. Operational Test of the Logics that activates the ELAC 1 & 2 and SEC1
R STBY PWR SPLY and Ability of the ELAC 1 and SEC 1 & 2 to Achieve Pitch
R Control
R NOTE : During the test, ignore the MASTER CAUT legend and single shime.____
R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------
R 1. Open the circuit breakers 15CE1 On the overhead panel 23VU:
R and 21CE1. - the FAULT legends of the FLT CTL/ELAC
R 1 and FLT CTL/SEC 1 pushbutton
R switches are off.
R 2. On the panel 50VU: On the panel 50VU:
R - release the BLUE PUMP OVRD - the ON legend of the BLUE PUMP OVRD
R pushbutton switch. pushbutton switch goes off.
R On the overhead panel 23VU:
R 1EFF : 001-049, 051-099, 101-105, 201-210, 1 27-96-00Page 573 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R R R
R R
R R R
R R R
R R R 3. On the panel 50VU: - push the BLUE PUMP OVRD pushbutton switch.
R R
R R R R 4. Close the circuit breakers 15CE1 and 21CE1.
R R R
R R R
R R R R R R 5. Open the circuit breakers 52GA (if installed), 1GA and 15CE2. NOTE : Ignore the warning related____ to the other systems
R R
-the FAULT legends of the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches are off.
After approximately 30 seconds the FAULT legends come on.
On the upper ECAM display unit, the ELAC 1 FAULT and SEC 1 FAULT warnings come into view.
On the lower ECAM display unit, the ELAC 1 and SEC 1 legends change to amber.
On the overhead panel 50VU:
-the ON legend of the BLUE PUMP OVRD pushbutton switch comes on.
The above mentioned warnings are still shown.
On the overhead panel 23VU:
-the FAULT legends of the FLT CTL/ELAC 1 and FLT CTL/SEC 1 pushbutton switches go off.
On the upper ECAM display unit, the ELAC 1 FAULT and SEC 1 FAULT warnings go out of view.
On the lower ECAM display unit, the ELAC 1 and SEC 1 legends change to green.
On the overhead panel 24VU:
-the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch comes on.
On the upper ECAM display unit, the ELAC 2 FAULT warning comes into view.
R 1EFF : 001-049, 051-099, 101-105, 201-203, 1 27-96-00Page 574 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R On the lower ECAM display unit, the
R ELAC 2 legend changes to amber.
R 6. Open the circuit breaker 19CE1. On the overhead panel 24VU:
R - the FAULT legend of the FLT CTL/ELAC
R 2 pushbutton switch goes off.
R On the upper ECAM display unit, the
R ELAC 2 FAULT warning go out of view.
R On the lower ECAM display unit, the
R ELAC 2 legend changes to green.
R After approximately 30 seconds:
R - On the lower ECAM display unit, the
R ELAC 2 legend changes to amber again.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵9(141)