ZONAL INSPECTION : LOWER HALF OF FUSELAGE - INSPECTION/CHECK
TASK 05-21-00-200-001
Zonal Inspection as far as visible from the Ground of the Lower Half of the
Fuselage
1. Reason for the Job
R R Self Explanatory
2. Job Set-up Information
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
53-35-00-200-002 Inspection of the Wing to Fuselage Fairings and Belly Fairing Access Panels for Missing Fasteners
3. Job Set-up
Subtask 05-21-00-869-050
A. Not Applicable
4. Procedure
Subtask 05-21-00-210-050
A. Inspection
(1)
Make a general visual inspection of the lower half of the fuselage from the ground during the aircraft walkaround.
(2)
Make sure that there are no signs of corrosion, cracks or damage.
(3)
Inspect the belly fairing access panels for missing fasteners (Ref. TASK 53-35-00-200-002)
TASK 05-21-00-200-002 Zonal Inspection of the Lower Half of the Fuselage
1.
Reason for the Job Refer to the MPD TASK: ZL-100-02
2.
Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 2.0 m (6 ft. 7 in.)
3. Job Set-up Subtask 05-21-00-010-050
A. Get Access
(1) Put an access platform in position near the lower half of the fuselage.
4. Procedure Subtask 05-21-00-210-051
A. Inspection
(1)
Make a general visual inspection of the lower half of the fuselage up to the Stringer 19 LH and RH and the doors surrounds.
(2)
Make sure that there is no damage, corrosion, leaks or cracks on all the parts of the components and the structure you can see.
5. Close-up Subtask 05-21-00-410-050
A. Close Access
(1) Remove the access platform(s).
ZONAL INSPECTION : RADOME - INSPECTION/CHECK TASK 05-21-10-200-001 Zonal Inspection of the Radome
1.
Reason for the Job Refer to the MPD TASK: ZL-110-01
2.
Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 2 m (6 ft. 7 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
53-15-11-010-001 Opening of the Radome 110AL 53-15-11-410-001 Closing of the Radome 110AL
3. Job Set-up Subtask 05-21-10-010-050
A. Get Access
(1)
Put an access platform in position at the zone 110.
(2)
Open the radome 110AL, (Ref. TASK 53-15-11-010-001).
NOTE : Two persons are necessary to open the radome.
4. Procedure Subtask 05-21-10-210-050
A. Inspection
(1)
Do a general visual inspection of the structure of the radome.
(2)
Make sure that there are no signs of corrosions, craks or damage .
(3)
Make sure that all the installations (wiring, equipment) are attached correctly.
5. Close-up Subtask 05-21-10-410-050
A. Close Access
(1)
Close the radome 110AL, (Ref. TASK 53-15-11-410-001).
NOTE : Two persons are necessary to close the radome.
(2)
Remove the access platform(s).
ZONAL INSPECTION : AVIONICS COMPARTMENT - INSPECTION/CHECK__________________________________________________________
TASK 05-21-20-200-001
R Zonal Inspection of the FWD Avionic Compartment (Zones 121 and 122)
1. Reason for the Job__________________
Refer to the MPD TASK: ZL-121-01
2. Job Set-up Information______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 2.5 m (8 ft. 2 in.)