A. Pressurization Control (continued)
CHART 1 FAULT ISOLATION (PRESSURIZATION SYSTEM) (Sheet 1-of 5)
Fault
Cabin will not pressurize.
Cause
Blockedsafetyvalve cabin
air filter or orifice.
Blockedcontrollercabin air
filter with orifice.
Internalmalfunctionin the
isobaricvalve.
Internal malfunction in the
safetyvalve.
Internal malfunction in the
controller.
Defective"q"switch and/or
landing gear safety switch.
Defectivedump/testswitch. No pressure to door seal.
Excessiveleakage in pressurization
ducts. Excessivecabin leakage. Solenoid valve malfunctions
in the open position.
Valve on outside air control
box won't close.
Malfunction of ECS control
switch.
Malfunction of ECU pressure regulator and shut off valve.
Remedy
Replacefilter and check orifice.
Clean filter and check orificeon controller.
Removeand replace isobaric valve.
Removeandreplace safety valve.
Remove and replace controller.
Removeand replace switch.
Replaceswitch.
Check and repair door
sealor door seal valve. Locateleakand tighten
connections. Locateand repair leak.
Replacevalve.
Adjust or lubricate valve or control linkage.
Repairor replace switch.
Repairor replace valve.
EFFECTIVITY:
040-999
2
PAGE 1-30-00
Jan10/90 21-30
PIPER AIRCRAFT
PA-42-720 (Advanced Trainer)
MAINTENANCE MANUAL
A. PressurizationControl(continued)
CHART 1 FAULT ISOLATION (PRESSURIZATION SYSTEM)
Fault Cause
Cabinpressurizesto full Vacuumtube not connected
positivedifferential to controller.
pressureafter takeoff.
Malfunctionin aircraft
vacuumsupply.
Rupturein volume tank.
Internal malfunction inthe
outflowisobaricvalve.
Internalmalfunctionin the
controller.
Cabinaltitudedecreases below selected altitude. Low aircraft vacuumsupply.
Minorleak in tube between
controllerand volume tank
or in volume tank.
Minorleak in tubebetween
controller and isobaric valve
or in isobaric valve.
Minorleak in the controller.
Minimumratesunbalanced. Minor leak in tube between Downrate faster than up controllerand volume tank rate. or in volume tank.
Minorleak in the controller.
Pressurizedoperation Solenoidvalve malfunction beforetakeoff and in the closed position. after landing.
"q" switch, landing gear squat switch or test/dump switchmalfunctionin the open position.
(Sheet 2 of 5)
Remedy
Connectvacuum tube.
Checkaircraft vacuum
supply.
Replace tank.
Removeand replace valve.
Removeand replace controller.
Checkaircraftvacuum supply.
Removeand replace tube or volume tank.
Remove and replacetube or isobaric valve.