S 015-117-N00
(5) Open the fan cowl panel (AMM 71-11-04/201).
S 045-119-N00
WARNING: DO THE THRUST REVERSER DEACTIVATION PROCEDURE TO PREVENT THE
_______ OPERATION OF THE THRUST REVERSER. THE ACCIDENTAL OPERATION OF THE THRUST REVERSER CAN CAUSE INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT.
(6)
Do this procedure: Thrust Reverser Deactivation for Ground Maintenance (AMM 78-31-00/201).
(7)
Open the core cowl panels (AMM 71-11-06/201).
S 015-118-N00
S 015-120-N00
WARNING: OBEY THE INSTRUCTIONS IN AMM 78-31-00/201 WHEN YOU OPEN THE
_______ THRUST REVERSERS. IF YOU DO NOT OBEY THE INSTRUCTIONS, INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT CAN OCCUR.
(8)
Open the thrust reversers (AMM 78-31-00/201).
S 035-008-N00
(9)
Disconnect the electrical connector DV351 from the start valve (Fig. 501).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
71-00-00
ALL ú ú N01 Page 509 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / PW4000 SERIES /747-400 / ENGINES /MAINTENANCE MANUAL ////////////////////////
SEE A
ELECTRICAL QUICK ATTACH-DETACHCONNECTOR (QAD) ADAPTERDV351MAIN
GEARBOX
START VALVE
FWD
STARTER
A
Start Valve Electrical Connector Location
Figure 501
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
71-00-00
ALL ú ú N01 Page 510 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
S 035-009-N00
(10) Disconnect the sense line for the PRV controller at the precooler (Fig. 502).
(a)
Install a cap on the sense line port on the precooler.
(b)
Keep the sense line open.
S 045-010-N00
(11)
Do the deactivation procedure for the HPSOV (AMM 36-11-05/201).
D.
Do the Pneumatic Leak Test
S 865-121-N00
(1) Make sure this circuit breaker is closed:
(a) P6 Main Power Distribution Panel
1) 6J18 ENG START AIR CONT
S 865-011-N00
(2)
On the main EICAS, make sure the left or right DUCT PRESS is at a minimum of 35.
S 865-012-N00
(3)
Pull out the applicable START switch.
S 865-013-N00
WARNING: USE A RATCHET WRENCH TO TURN THE MANUAL OVERRIDE DRIVE FOR THE
_______ PRV. THE PRV CAN QUICKLY OPEN WHEN YOU TURN THE MANUAL OVERRIDE DRIVE. IF YOU DO NOT USE A RATCHET-DRIVE WRENCH, THE MANUAL OVERRIDE DRIVE CAN PULL THE WRENCH OUT OF YOUR HANDS AND CAUSE INJURY TO YOU.
CAUTION: DO NOT TURN THE MANUAL OVERIDE DRIVE FOR THE PRSOV OR THE PRV
_______ MORE THAN 45 DEGREES. IF YOU TURN THE MANUAL OVERRIDE DRIVE MORE THAN 45 DEGREES, DAMAGE TO THE POSITION SWITCH CAN OCCUR.
(4) Manually turn the override drive shaft for the PRV with a 1/2-inch hex wrench, until the position indicator moves to the OPEN position (Fig. 502).