• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-13 07:54来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 S 214-012

 (7)  
Make sure the finish of the surface of the static pressure port is 63 RHR maximum.

 S 214-014

 (8)  
Make sure that all of the inlet holes on the static pressure port are free of blockage.

 S 214-028

 (9)  
Make sure that the inlet holes in the static pressure port are not damaged.

 S 214-022

 (10)
 Make sure no unwanted materials are inside the static pressure port.

 S 374-013

 (11)
 Apply alodine on the external surface of the static pressure port (Ref 51-21-04/701).


 S 434-015
 CAUTION:_______DO NOT TWIST THE STATIC HOSE. YOU CAN CAUSE THE STATIC HOSE OR THE CONNECTION TO BE DAMAGED.
 (12) Connect the static hose to the pressure port:
 (a)  Remove the dust cap from the static hose.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-11-02
 ALL  ú ú 01 Page 405 ú Jun 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (b) Connect the static hose to the static pressure port.
 S 794-027
 (13)
 Do a leakage test of the pitot-static system (Ref 34-11-00/501).

 S 434-017

 (14)
 Apply a pressure fillet seal all around the static pressure port and the nut (Ref 51-31-01/201).

 S 414-018

 (15)
 For the left and the right alternate static pressure ports, install the wall (Ref 25-52-01/401).


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-11-02
 ALL  ú ú 01 Page 406 ú Jun 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 SOURCE SELECT VALVE - REMOVAL/INSTALLATION
__________________________________________
 1.  General
_______
 A.  This subject contains two tasks. The first task is to remove a source select valve. The second task is to install a source select valve. The second task includes a test of the source select valve.
 B.  A source select valve is installed in the main equipment center. This valve is for the pitot system and the static system. The valve is installed on the aft side of the floor beam at sta 440.
 TASK 34-11-03-004-030
 2.  Source Select Valve Removal (Fig. 401)
___________________________
 A.  Access
 (1)  
Location Zone 117 Electrical and Electronics Compartment, LH

 (2)  
Access Panel
 117AL Electronics Compartment Access Door

 

 B.  Remove the Source Select Valve
 S 864-002
 (1)  
Open this circuit breaker and attach a DO-NOT-CLOSE tag:

 (a)  P7 Overhead Circuit Breaker Panel
 1) 7J17 ADC C P/S XFR VALVE


 (2)  
Remove the source select valve:


 S 024-026
 CAUTION: DO NOT DISCONNECT THE PITOT-STATIC SYSTEM HOSES WHEN THE
_______ PITOT-STATIC SYSTEM IS NOT AT AMBIENT PRESSURE. YOU CAN CAUSE DAMAGE TO THE SOURCE SELECT VALVE.
 (a)  
Remove the pitot-static system hoses from the valve.

 (b)  
Install dust caps on the hoses.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-11-03
 ALL  ú ú 02 Page 401 ú Feb 10/94
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

AFT SIDE OF FLOOR
BEAM AT STA 440 
SEE  B 
MAIN EQUIPMENT CENTER 
QUICK-DISCONNECTS 
PITOT-STATIC 
QUICK-DISCONNECTS  SOURCE SELECT 
VALVE 
ELECTRICAL 
CONNECTOR 

AFT SIDE OF FLOOR BEAM AT STA 440
B

Source Select Valve - Removal/Installation
Figure 401

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 导航 NAVIGATION 1(80)