• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-13 07:54来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 S 865-280
 WARNING: MAKE SURE THAT YOU DO NOT APPLY ELECTRICAL POWER TO THE FLIGHT
_______ CONTROLS. FLIGHT CONTROL SURFACES CAN MOVE AUTOMATICALLY WHEN YOU PRESSURIZE THE PITOT-STATIC SYSTEM. THIS CAN CAUSE INJURIES TO PERSONS AND DAMAGE TO EQUIPMENT.
 CAUTION: MAKE SURE THAT YOU DO NOT APPLY ELECTRICAL POWER TO THE
_______ PITOT-STATIC PROBE HEATERS. YOU CAN CAUSE DAMAGE TO THE PITOT-STATIC PROBES.
 (1)  Open these circuit breakers and attach DO-NOT-CLOSE tags:
 (a)  P6 Main Power Distribution Panel
 1) 6D31 PROBE HEAT PITOT R
 2) 6D32 PROBE HEAT AUX PITOT L
 3) 6E01 PRIM T/E FLAP CONT AC

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-11-00
 ALL  ú ú 05 Page 536 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL 4) 6E02 PRIM T/E FLAP CONT DC S 865-492
 WARNING: WHEN THE STATIC PORTS ARE COVERED, MAKE SURE THAT CONDITION IS
_______ VISIBLE FORM THE GROUND. FAILURE TO OBSERVE AND REMOVE COVERINGS OVER STATIC PORTS BEFORE FLIGHT MAY CAUSE LARGE ERRORS ON AIRSPEED SENSING AND ALTITUDE SENSING SIGNALS, WHICH MAY LEAD TO LOSS OF SAFE FLIGHT.
 WARNING:_______MAKE SURE THAT THE PROBE HEAT IS NOT ON. YOU CAN CAUSE INJURY TO PERSONS.
 CAUTION:_______DO NOT EXTEND THE SEALS INTO THE PITOT DRAINS. YOU CAN CAUSE DAMAGE TO THE SURFACE IN THE AREA WHEN YOU REMOVE THE SEALS.
 (2)  Seal these locations with vinyl adhesive tape:
 (a)  
The forward static ports (S1) in the lower left pitot-static probe.

 (b)  
The aft static ports (S2) in the upper right pitot-static probe.


 S 865-202
 CAUTION:_______DISCONNECT THE SOURCE SELECT VALVE FROM THE STATIC SYSTEM. YOU CAN CAUSE DAMAGE TO THE AIR DATA COMPUTER.
 (3)  
Disconnect the auxiliary No. 2 static system from the input of the source select valve.

 S 865-203

 (4)  
Connect the pneumatic test set to the auxiliary No. 2 static system test fitting.

 (a)  
Connect the static (vacuum) source in the pneumatic test unit through the static control valve to the static cutoff valve.

 (b)  
Connect the quick-disconnect test fitting of the auxiliary No. 2 static system to the static cutoff valve through the static system test gage and flow restrictor.

 


 NOTE: You will find the test fitting on the right side of the
____ airplane above the system drains at STA 400.
 (c)  Open the static cutoff valve.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 34-11-00
 ALL  ú ú 05 Page 537 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 S 865-204
 CAUTION:_______DISCONNECT THE SOURCE SELECT VALVE FROM THE STATIC SYSTEM. YOU CAN CAUSE DAMAGE TO THE EQUIPMENT.
 (5)  Do a leak test on the auxiliary No. 2 static system (full-range).
 (a)  Apply pressure to the auxiliary No. 2 static system equivalent to 25,000 |200 feet of altitude (11.10 |0.10 in. Hg absolute).
 CAUTION: MAKE SURE THAT YOU HOLD THE PRESSURE BEHIND THE CUTOFF
_______ VALVE DURING THE CUTOFF TIME. YOU CAN CAUSE DAMAGE TO THE EQUIPMENT WHEN YOU OPEN THE CUTOFF VALVE WITHOUT THE PRESSURE.
 (b)  
Close the static cutoff valve to the system when the instrument shows the necessary altitude.

 (c)  
Stop for 5 to 6 minutes to permit the system to become stable.

 (d)  
Write the altitude.

 (e)  
Stop for 1 minute and read the altitude again.

 (f)  
Make sure that the altitude does not go down by more than 400 feet (0.20 in. Hg).


 S 845-206
 (6)  
Open the static cutoff valve.

 S 865-277

 (7)  
Put the auxiliary No. 2 static system to ambient pressure.


 S 865-395
 CAUTION: DO NOT DISCONNECT THE PNEUMATIC TEST SET WHEN THE PITOT-STATIC
_______ SYSTEM IS NOT AT AMBIENT PRESSURE. YOU CAN CAUSE DAMAGE TO THE EQUIPMENT.
 (8)  
Disconnect the pneumatic test set from the test fitting.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 导航 NAVIGATION 1(51)