 (1) Use a MISCELLANEOUS (Material No. 19-003), made moist with CLEANING AGENTS (Material No. 11-004) to clean the aileron upper and lower skins at the attachment to the spars and ribs.
 Subtask 57-60-00-210-053
 B. Inspection
 (1) Examine the upper and lower skins at the attachment to the spars and ribs. Make sure that:
 -
there is no damage

 -
there is no delamination

 -
there are no cracks


 -the surface protection is in the correct condition.
 NOTE : If necessary, refer to the ASRM (Ref. ASRM 576000) for the
____
 correct repair procedure.

 5. Close-up
________
 Subtask 57-60-00-865-057
 A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 5CV, 7CV, 15CE1, 15CE2, 16CE1, 16CE2.
 1EFF : ALL 1 57-60-00Page 623 1 1 Aug 01/99R 1 1 1CES 1


 Subtask 57-60-00-942-053

 B. Removal of Equipment
 (1)
 Remove the TOOL-ZERO LOCKING, FLAP SLAT CTL LEVER (98D27803500001) from the flap/slat control lever.

 (2)
 Remove the warning notice(s).

 (3)
 Remove the access platform(s).

 (4)
 Remove the safety barriers.

 (5)
 Remove the ground support and maintenance equipment, the special and standard tools and all other items.


 1EFF : ALL 1 57-60-00Page 624 1 1 Aug 01/99R 1 1 1CES 1


 TASK 57-60-00-210-001
 Detailed Visual Inspection of Aileron Upper and Lower Skins, External Surface
 WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
 START A TASK ON OR NEAR:

 -
THE FLIGHT CONTROLS

 -
THE FLIGHT CONTROL SURFACES

 -
THE LANDING GEAR AND THE RELATED DOORS


 -COMPONENTS THAT MOVE.
 WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
 GEAR.

 CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
_______
 -
DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.

 -
DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.


 -MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
 1. Reason for the Job
__________________
 Refer to the MPD TASK: 576106-01
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 No specific warning notices
 No specific access platform 3.8 m (12 ft. 6 in.)
 98D27903500000 2 PIN-SIDE STICK LOCKING

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
ASRM 57600000  (for corrective action)
R  ASRM 576121 PB201 (for corrective action) CMM 576121 (for corrective action) 57-60-00-991-005 Fig. 605


 3. Job Set-up__________
 Subtask 57-60-00-941-055
 A. Safety Precautions
 (1) Install the PIN-SIDE STICK LOCKING (98D27903500000) on the CAPT and F/O side sticks.
 (2) Put the warning notices on the side sticks to tell persons not to touch the side sticks.
 (3) Put the safety barriers in position.
 Subtask 57-60-00-865-058
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FLIGHT CONTROLS/ELAC1/NORM/SPLY 15CE1 B11 49VU FLIGHT CONTROLS/SLT/CTL AND MONG/SYS1 5CV B06 105VU FLIGHT CONTROLS/ELAC2/STBY SPLY 16CE2 A02 105VU FLT CTL/ELAC1/STBY SPLY 16CE1 A01 121VU FLIGHT CONTROLS/SLT/CTL/SYS2 7CV R21 121VU FLIGHT CONTROLS/ELAC2/NORM/SPLY 15CE2 R20
 Subtask 57-60-00-010-051
 C. Get Access
 (1) Put the access platform below the zone 590(690).
 4. Procedure_________
 (Ref. Fig. 605/TASK 57-60-00-991-005) 
R R R R R R  CAUTION : BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING_______ EDGE: - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS. - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS. - MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
 