R (b) Set the access panel (2) so that:
R - dimension X is between 0.1 mm (0.0039 in.) and 4.3 mm (0.1692
R in.) along the full length of the panel. Try and set the
R clearance as near as possible to 2.0 mm (0.0787 in.).
R - dimension Z is between 3.0 mm (0.1181 in.) and 6.0 mm (0.2362
R in.) along the full width of the panel inboard end. Try and set
R the clearance as near as possible to 4.0 mm (0.1574 in.).
R (c) Attach the access panel (2) to the wing with the remaining camloc
R fasteners (1).
R (d) Fill the clearance between the access panel (2) and the trailing
R edge of the wing skin with SEALANTS (Material No. 09-016).
R (3) Install the access panel 575CB(675CB) (12) as follows:
R (a) Put the access panel (12) in position and attach it with two of
R the outer camloc fasteners (11).
R (b) Set the access panel (12) so that:
R - dimension X is between 0.1 mm (0.0039 in.) and 4.3 mm (0.1692
R in.) along the full length of the panel. Try and set the
R clearance as near as possible to 2.0 mm (0.0787 in.).
R - dimension Z is between 3.0 mm (0.1181 in.) and 6.0 mm (0.2362
R in.) along the full width of the panel outboard end. Try and
R set the clearance as near as possible to 4.0 mm (0.1574 in.).
R (c) Attach the access panel (12) to the wing with the remaining
R camloc fasteners (11).
R (d) Fill the clearance between the access panel (12) and the trailing
R edge of the wing skin with SEALANTS (Material No. 09-016).
R (4) Install the access panel 575DB(675DB) (10) as follows:
R (a) Put the access panel (10) in position and attach it with two of
R the outer camloc fasteners (9).
R (b) Set the access panel (10) so that:
R - dimension X is between 0.1 mm (0.0039 in.) and 4.3 mm (0.1692
R in.) along the full length of the panel. Try and set the
R clearance as near as possible to 2.0 mm (0.0787 in.).
R - dimension Z is between 3.0 mm (0.1181 in.) and 6.0 mm (0.2362
R in.) along each full width of the panel. Try and set the two
R clearances as near as possible to 4.0 mm (0.1574 in.).
R (c) Attach the access panel (10) to the wing with the remaining
R camloc fasteners (9).
R (d) Fill the clearance between the access panel (10) and the trailing
R edge of the wing skin with SEALANTS (Material No. 09-016).
R (5) Install the access panel 575EB(675EB) (8) as follows:
R (a) Put the access panel (8) in position and attach it with two of
R the outer camloc fasteners (7).
R (b) Set the access panel (8) so that:
R - dimension X is between 0.1 mm (0.0039 in.) and 4.3 mm (0.1692
R in.) along the full length of the panel. Try and set the
R clearance as near as possible to 2.0 mm (0.0787 in.).
R - dimension Z is between 3.0 mm (0.1181 in.) and 6.0 mm (0.2362
R in.) along each full width of the panel. Try and set the two
R clearances as near as possible to 4.0 mm (0.1574 in.).
R (c) Attach the access panel (8) to the wing with the remaining camloc
R fasteners (7).
R (d) Fill the clearance between the access panel (8) and the trailing
R edge of the wing skin with SEALANTS (Material No. 09-016).
R (6) Install the access panel 575FB(675FB) (6) as follows:
R (a) Put the access panel (6) in position and attach it with two of
R the outer camloc fasteners (5).
R (b) Set the access panel (6) so that:
R - dimension X is between 0.1 mm (0.0039 in.) and 4.3 mm (0.1692
R in.) along the full length of the panel. Try and set the
R clearance as near as possible to 2.0 mm (0.0787 in.).
R - dimension Z is between 3.0 mm (0.1181 in.) and 6.0 mm (0.2362
R in.) along the full width of the panel inboard end. Try and set
R the clearance as near as possible to 4.0 mm (0.1574 in.).
R (c) Attach the access panel (6) to the wing with the remaining camloc
R fasteners (5).
R (d) Fill the clearance between the access panel (6) and the trailing
R edge of the wing skin with SEALANTS (Material No. 09-016).