 2_ Measure the dimension X:
 - make sure it is between 2.4 mm (0.0944 in.) and 2.6 mm
 (0.1023 in.).

 (b) For an in service lockstay or sidestay:
 1 Measure the dimension Z:
_
 -make sure it is between 1.05 mm (0.0413 in.) and 1.95 mm (0.0767 in.).
 2 Measure the dimension X:
_
 -make sure it is between 2.2 mm (0.0866 in.) and 2.8 mm (0.1102 in.).
 (c) If the dimensions are incorrect, do the adjustment of the MLG downlock proximity sensors 16GA (17GA) (Ref. TASK 32-31-73-820-001).
 (3)
 For the MLG extension proximity sensors 20GA (21GA) (System 1): (Ref. Fig. 603/TASK 32-31-73-991-012)

 (a)
 Measure the dimension Z:

 -make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0629 in.).

 (b)
 Measure the dimension X:

 -make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).

 (c)
 If the dimensions are incorrect, do the adjustment of the MLG extension proximity sensors 20GA (21GA) (Ref. TASK 32-31-73-820-002).

 

 (4)
 For the MLG extension proximity sensors 22GA (23GA) (System 2): (Ref. Fig. 603/TASK 32-31-73-991-012)

 (a)
 Measure the dimension Z:

 -make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0629 in.).

 (b)
 Measure the dimension X:

 -make sure it is between 3.9 mm (0.1535 in.) and 4.1 mm (0.1614 in.).

 (c)
 If the dimensions are incorrect, do the adjustment of the MLG extension proximity sensors 22GA (23GA) (Ref. TASK 32-31-73-820-002).

 


R 1EFF : 001-003, 051-052, 1 32-31-73Page 607 1 1 May 01/05 1 1 1CES 1


R  MLG Extension Proximity Sensor Figure 603/TASK 32-31-73-991-012
 1EFF : 1 1 1CES  ALL  1 111 32-31-73 Page 608 Nov 01/99

 

 (5) For the MLG door open proximity sensors 32GA (33GA), 34GA (35GA): (Ref. Fig. 604/TASK 32-31-73-991-013)
 (a)
 Measure the dimension X:

 -make sure it is between -2.5 mm (-0.0984 in.) and 2.5 mm (0.0984 in.).

 (b)
 Measure the dimension Z:

 -make sure it is between 1.5 mm (0.0590 in.) and 2.5 mm (0.0984 in.).

 (c)
 If the dimensions are incorrect, do the adjustment of the MLG door open proximity sensors 32GA (33GA), 34GA (35GA) (Ref. TASK 32-31-73-820-003).


R **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 401-499,
 Subtask 32-31-73-220-077-B
 A. Inspection of the MLG Proximity Sensor and Target Clearances
 (1) For the MLG downlock proximity sensors 14GA (15GA) (System 1): (Ref. Fig. 601/TASK 32-31-73-991-010)
 (a) For a new MLG lockstay or sidestay:
 1 Measure the dimension Z:

_
 -make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm (0.0629 in.).
 2 Measure the dimension X:
_
 -make sure it is between 0.7 mm (0.0275 in.) and 0.9 mm (0.0354 in.).
 (b) For an in service MLG lockstay or sidestay: 1 Measure the dimension Z:
_
 -make sure it is between 0.6 mm (0.0236 in.) and 2.4 mm (0.0944 in.).
 2 Measure the dimension X:
_
 -make sure it is between 0.35 mm (0.0137 in.) and 1.25 mm (0.0492 in.).
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 32-31-73Page 609 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1


R  MLG Door Open Proximity Sensor Figure 604/TASK 32-31-73-991-013
 1EFF : 1 1 1CES  ALL  1 111 32-31-73 Page 610 Nov 01/99

 

 (c) If the dimensions are incorrect, do the adjustment of the MLG downlock proximity sensors 14GA (15GA) (Ref. TASK 32-31-73-820-001).
 (2) For the MLG downlock proximity sensors 16GA (17GA) (System 2): (Ref. Fig. 602/TASK 32-31-73-991-011)
 (a)
 For a new MLG lockstay or sidestay:

 (b)
 For an in service lockstay or sidestay:


 1_ Measure the dimension Z:
 - make sure it is between 1.4 mm (0.0551 in.) and 1.6 mm
 (0.0629 in.).
 2_ Measure the dimension X:
 - make sure it is between 2.4 mm (0.0944 in.) and 2.6 mm
 (0.1023 in.).

 1 Measure the dimension Z:
_
 -make sure it is between 1.05 mm (0.0413 in.) and 1.95 mm (0.0767 in.).
 2 Measure the dimension X:
_
 -make sure it is between 2.2 mm (0.0866 in.) and 2.8 mm (0.1102 in.).
 (c) If the dimensions are incorrect, do the adjustment of the MLG downlock proximity sensors 16GA (17GA) (Ref. TASK 32-31-73-820-001).
 (3) For the MLG extension proximity sensors 20GA (21GA) (System 1): (Ref. Fig. 603/TASK 32-31-73-991-012)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LANDING GEAR 起落架5(89)