(d)
Remove the nuts (57), the washers (56), the capscrews (59) and the proximity- sensor (55).
(e)
If it is necessary to remove the target (51), remove the:
-nuts (54)
-washers (53)
-capscrews (50)
-target (51)
-spacer (52) if installed.
(5)
For the MLG-extension proximity-sensors 21GA(20GA) (System 1): (Ref. Fig. 404/TASK 32-31-73-991-004)
(a)
Disconnect the electrical connector (71) from the applicable proximity-sensor (72):
-
for System 1, LH, disconnect FIN 21GA
-
for System 1, RH, discinnect FIN 20GA.
(b)
Put blanking caps on the disconnected electrical connectors.
(c)
Identify the positions of the proximity-sensor (72), the target
(77) and the spacer (76) if installed, before you remove them.
(d)
Remove the nuts (74), the washers (75), the capscrews (79), and the proximity- sensor (72).
(e)
If it is necessary to remove the target (77), remove the:
-nuts (82)
-washers (81)
-capscrews (78)
-target (77)
-spacer (76) if installed.
1EFF : ALL 1 32-31-73Page 407 1 1 Aug 01/04R 1 1 1CES 1
R MLG Downlock Proximity-Sensors (System 2) Figure 403/TASK 32-31-73-991-003
1EFF : 1 1 1CES ALL 1 111 32-31-73 Page 408 Feb 01/04
R MLG Extension Proximity-Sensors (System 1 and 2) Figure 404/TASK 32-31-73-991-004
1EFF : 1 1 1CES ALL 1 111 32-31-73 Page 409 Feb 01/04
(6)
For the MLG-extension proximity sensors 23GA(22GA) (System 2): (Ref. Fig. 404/TASK 32-31-73-991-004)
(a)
Disconnect the electrical connector (83) from the applicable proximity-sensor (90):
-
for System 2, LH, disconnect FIN 23GA
-
for System 2, RH, disconnect FIN 22GA.
(b)
Put blanking caps on the disconnected electrical connectors.
(c)
Identify the positions of the proximity-sensor (90), the target
(87) and the spacer (86) if installed, before you remove them.
(d)
Remove the nuts (92), the washers (91), the capscrews (85) and the proximity- sensor (90).
(e)
If it is necessary to remove the target (87), remove the:
-nuts (88)
-washers (89)
-capscrews (84)
-target (87)
-spacer (86) if installed.
(7)
For the MLG-door open proximity-sensors 33GA(32GA), 35GA(34GA): (Ref. Fig. 405/TASK 32-31-73-991-005)
(a)
Disconnect the electrical connector (106) from the applicable proximity-sensor (114):
-
for System 1, LH, disconnect FIN 33GA
-
for System 1, RH, disconnect FIN 32GA
-
for System 2, LH, disconnect FIN 35GA
-
for System 2, RH, disconnect FIN 34GA.
(b)
Put blanking caps on the disconnected electrical connectors.
(c)
Identify the positions of the proximity-sensor (114), the target
(108) and the spacer (109) if installed, before you remove them.
(d)
Remove the nuts (103), the washers (104), the bolts (113) and the proximity-sensor (114).
(e)
If it is necessary to remove the target (108), remove the:
-nuts (111)
-washers (112)
-bolts (107)
-target (108)
-spacer (109) if installed.
1EFF : ALL 1 32-31-73Page 410 1 1 Aug 01/04R 1 1 1CES 1
R MLG Door-Open Proximity-Sensors Figure 405/TASK 32-31-73-991-005
1EFF : 1 1 1CES ALL 1 111 32-31-73 Page 411 Feb 01/04
TASK 32-31-73-400-001
Installation of the Proximity-Sensors 9GA(8GA), 11GA(10GA), 27GA(26GA),
29GA(28GA), 15GA(14GA), 17GA(16GA), 21GA(20GA), 23GA(22GA), 33GA(32GA)...
WARNING : MAKE SURE THAT THE FLIGHT CONTROL SAFETY-LOCKS AND THE WARNING
_______
NOTICES ARE IN POSITION.
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LANDING GEAR 起落架5(47)