 Open the NLG doors (Ref. TASK 32-22-00-010-001).

 (2)
 Make sure that a SAFETY PIN - NLG DOOR is installed in each NLG door.


 1EFF : ALL 1 32-33-00Page 549 1 1 Aug 01/05 1 1 1CES 1


 (3)
 Open the MLG doors (Ref. TASK 32-12-00-010-001).

 (4)
 Make sure that a GROUND LOCK SLEEVE (460005835) is installed on each MLG door.

 (5)
 Open the forward cargo-compartment door 825 (Ref. TASK 52-30-00-860-001).

 (6)
 Remove the forward cargo-compartment ceiling-panels 131MC, 131NC.

 (7)
 Remove the cockpit floor panels 211FF, 211JF (Ref. TASK 53-12-11-000-001).

 (8)
 Remove the passenger compartment floor panels 241EF, 242FF (Ref. TASK 53-32-12-000-002).


 **ON A/C ALL
 Subtask 32-33-00-869-070
 C. Flight Configuration Precautions
 (1)
 If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002). Then, it is not necessary to operate the LGCIU circuit breakers.

 (2)
 If the electrical power is necessary, do the precautions for flight configuration (Ref. TASK 32-00-00-860-001) before you open the LGCIU circuit breakers.


 Subtask 32-33-00-865-059
 D. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU L/G/LGCIU/SYS1/NORM 1GA C09 121VU HYDRAULIC/LGCIU/SYS2 2GA Q35 121VU HYDRAULIC/LGCIU/SYS1/GRND SPLY 52GA Q34
 1EFF : ALL 1 32-33-00Page 550 1 1 Aug 01/05R 1 1 1CES 1


 4. Procedure_________
 CAUTION : MAKE SURE THAT THE FREE-FALL EXTENSION CABLES ARE ADJUSTED_______ CORRECTLY. INCORRECT ADJUSTMENT OF THE CABLES CAN CAUSE THE FREE-FALL EXTENSION SYSTEM TO BE UNSERVICEABLE.
 Subtask 32-33-00-480-059
 A. Installation of the Rigging Pins (Ref. Fig. 505/TASK 32-33-00-991-013)
 (1) Install the RIGGING PIN (98A27801001000) at position Pin 12 and Pin 1.
 (2) Install the RIGGING PIN (98DNSA20208060) at position Pin 2 and Pin 11.
 (3) Make sure that the related parts are locked.
 NOTE : If the rigging pins can not be installed, adjust the MLG____ mechanical system (Ref. TASK 32-33-00-820-004).
 Subtask 32-33-00-820-054 
R  B. Adjustment of the cables (1) and (2)
R R R  (1) Attach the tensiometer to the cable (1) at position A in the forward cargo compartment, zone 131(132). Make sure that the tensiometer is attached a minimum of 80 mm (3.1496 in.) away from pulleys or turnbuckles.
 (2) Get the ambient temperature and the temperature of the underfloor area.
 (3) Remove the two locking clips (16) from the turnbuckle body (17) between the cables (1) and (2).
 (4) Plot the ambient and underfloor temperature points on the graph and find the correct tension value. (Ref. Fig. 508/TASK 32-33-00-991-014)
 NOTE : When the points of the ambient temperature and the underfloor____ temperature meet between the given lines of tension, then the correct tension reading will be calculated by linear extrapolation. (See the example on the graph). (Ref. Fig. 508/TASK 32-33-00-991-014)

 1EFF : ALL 1 32-33-00Page 551 1 1 Aug 01/05 1 1 1CES 1


 MLG Cable-Tension Graph Figure 508/TASK 32-33-00-991-014
 1EFF : 1 1R 1CES  ALL  1 11 1 32-33-00 Page 552 Nov 01/02

 

R  (5) Operate the tensiometer. If necessary, adjust the turnbuckle body 
R  (17) until the tensiometer shows the same value as you found on the 
R  graph. 
R  NOTE : Get five tensiometer indications from the same position on the____ 
R  cable. Use the middle indication as the correct value. Ignore 
R  the two lowest and the two highest indication values.
 (6) Release the tensiometer. 

R  (7) Safety the ends of the cables (1) and (2) and the turnbuckle body 
R  (17) with the two locking clips (16). 
R  NOTE : If necessary, increase the cable tension to align the locking____ 
R  clips (16) and the turnbuckle body (17). Do not decrease the 
R  cable tension to align the locking clips (16) and the 
R  turnbuckle body (17). 
R  (8) Remove the tensiometer.
 Subtask 32-33-00-820-055
 C. Adjustment of the cables (3) and (4)
 (1) Do the procedure as for the cables (1) and (2), specified in
 paragraph 4. B.
 