Subtask 32-31-73-865-050
D. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
49VU L/G/LGCIU/SYS1/NORM 1GA C09 121VU HYDRAULIC/LGCIU/SYS2 2GA Q35 121VU HYDRAULIC/LGCIU/SYS1/GRND SPLY 52GA Q34
4. Procedure
_________
Subtask 32-31-73-020-068
A. Removal of the Proximity-Sensors
(1) For the MLG-uplock proximity-sensors 9GA(8GA), 11GA(10GA): (Ref. Fig. 401/TASK 32-31-73-991-001)
(a) Disconnect the electrical connector (6) from the applicable R MLG-uplock proximity-sensor (4):
-
for System 1, LH, disconnect FIN 9GA
-
for System 1, RH, disconnect FIN 8GA
-
for System 2, LH, disconnect FIN 11GA
-
for System 2, RH, disconnect FIN 10GA.
(b)
Put blanking caps on the disconnected electrical connectors.
(c)
Remove and discard the lockwire from the capscrews (1).
(d)
Identify the positions of the bracket (3) and the proximity sensor (4) before you remove them.
(e)
Remove the capscrews (1) and the washers (2). Remove the bracket
(3) together with the proximity-sensor (4).
(f)
Remove the nuts (5), the capscrews (8) and the washers (7).
(g)
Remove the bracket (3) from the proximity-sensor (4).
1EFF : ALL 1 32-31-73Page 403 1 1 May 01/05 1 1 1CES 1
R MLG Uplock and Door Uplock Proximity-Sensors Figure 401/TASK 32-31-73-991-001
1EFF : 1 1 1CES ALL 1 111 32-31-73 Page 404 Feb 01/04
(2)
For the MLG door-uplock proximity-sensors 27GA(26GA), 29GA(28GA): (Ref. Fig. 401/TASK 32-31-73-991-001)
(a)
Disconnect the electrical connector (15) from the applicable door uplock proximity-sensor (9):
-
for System 1, LH, disconnect FIN 27GA
-
for System 1, RH, disconnect FIN 26GA
-
for System 2, LH, disconnect FIN 29GA
-
for System 2, RH, disconnect FIN 28GA.
(b)
Put blanking caps on the disconnected electrical connectors.
(c)
Remove and discard the lockwire from the capscrews (12).
(d)
Identify the positions of the bracket (10) and the proximity sensor (9) before you remove them.
(e)
Remove the capscrews (12) and the washers (11). Remove the bracket (10) together with the proximity-sensor (9).
(f)
Remove the nuts (16), the capscrews (13) and the washers (14).
(g)
Remove the bracket (10) from the proximity-sensor (9).
(3)
For the MLG-downlock proximity-sensors 15GA(14GA): (Ref. Fig. 402/TASK 32-31-73-991-002)
(a)
Disconnect the electrical connector (29) from the applicable proximity-sensor (37):
-
for System 1, LH, disconnect FIN 15GA
-
for System 1, RH, disconnect FIN 14GA.
(b)
Put blanking caps on the disconnected electrical connectors.
(c)
Remove and discard the lockwire from the capscrews (36).
(d)
Identify the positions of the proximity-sensor (37), the target
(31) and the spacer (32) if installed, before you remove them.
(e)
Remove the capscrews (36) and the proximity-sensor (37) from the lockstay.
(f)
If it is necessary to remove the target (31), remove the:
-nuts (34)
-washers (35)
-capscrews (30)
-target (31)
1EFF : ALL 1 32-31-73Page 405 1 1 Aug 01/04R 1 1 1CES 1
R MLG Downlock Proximity-Sensors (System 1) Figure 402/TASK 32-31-73-991-002
1EFF : 1 1 1CES ALL 1 111 32-31-73 Page 406 Feb 01/04
-spacer (32) if installed.
(4)
For the MLG-downlock proximity-sensors 17GA(16GA) (System 2): (Ref. Fig. 403/TASK 32-31-73-991-003)
(a)
Disconnect the electrical connector (60) from the applicable proximity-sensor (55):
-
for System 2, LH, disconnect FIN 17GA
-
for System 2, RH, disconnect FIN 16GA.
(b)
Put blanking caps on the disconnected electrical connectors.
(c)
Identify the positions of the proximity-sensor (55), the target
(51) and the spacer (52) if installed, before you remove them. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM LANDING GEAR 起落架5(46)