R No specific Torque Wrench : range 0.00 to 1.20 m.daN R (0.00 to 9.00 lbf.ft) No specific Torque Wrench : range 0.20 to 3.60 m.daN
(2.00 to 26.00 lbf.ft) 460005832 1 SPRING EXPANDER-MLG SIDE STAY 460005833 1 GROUND LOCK SLEEVE 460005835 1 GROUND LOCK SLEEVE 460005842 1 LAMP BOX 460006428 1 SETTING BLOCK 460006429 1 SETTING BLOCK 460007262 1 CHECKING GAUGE 460007280 1 GROUNDLOCK SLEEVE
1EFF : ALL 1 32-31-73Page 501 1 1 May 01/05 1 1 1CES 1
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 13-002 USA MIL-C-5541 MIL-C-81706 CLASS I/A CHEMICAL CONVERSION COATING YELLOW ALUMINUM (Ref. 20-31-00)
Material No. 19-010 USA AMS 5687 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
07-11-00-581-001 Lifting for Aircraft Maintenance Operations
07-11-00-582-002 Jacking - General
24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
29-10-00-864-001 Depressurize the Green Hydraulic System
29-14-00-614-001 Depressurization of the Hydraulic Reservoirs
29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
the Ground Connector
29-23-00-860-001 Disconnection of the Isolation Coupling of the Power
Transfer Unit (PTU)
29-23-00-860-002 Connection of the Isolation Coupling of the Power
Transfer Unit (PTU)
32-00-00-481-001 Installation of the Safety Devices on the Landing
Gears
32-00-00-481-002 Installation of the Safety Devices on the Landing
Gear Doors
32-00-00-860-001 Flight Configuration Precautions with Electrical
Power
32-00-00-860-002 Ground Configuration after Flight Configuration with
Electrical Power
32-11-19-000-001 Removal of the MLG Lock Springs
32-11-19-400-001 Installation of the MLG Lock Springs
32-12-00-010-001 Open the Main Gear Doors for Access
32-12-00-410-001 Close the Main Gear Doors after Access
32-69-00-740-001 BITE Check Landing Gear Control Interface Unit
(LGCIU) using MCDU to Ensure that Continuous BITE is
Operative
1EFF : ALL 1 32-31-73Page 502 1 1 May 01/05R 1 1 1CES 1
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
32-31-73-991-016 Fig. 501
32-31-73-991-018 Fig. 502
32-31-73-991-019 Fig. 503
32-31-73-991-020 Fig. 504
3. Job Set-up
__________
Subtask 32-31-73-941-058
A. Safety Precautions
(1)
Put the safety barriers in position.
(2)
Make sure that the ground safety locks are installed on the landing gear (Ref. TASK 32-00-00-481-001).
(3)
On the panel 400VU:
-make sure that the landing-gear control-lever 6GA is in the DOWN position
-put a warning notice in position to tell persons not to operate the landing gear and the MLG doors.
Subtask 32-31-73-860-057
B. Aircraft Maintenance Configuration
(1)
Make sure that the Green hydraulic system is depressurized (Ref. TASK 29-10-00-864-001).
(2)
Depressurize the applicable hydraulic reservoir (Ref. TASK 29-14-00-614-001).
(3)
Disconnect the isolation coupling of the PTU (Ref. TASK 29-23-00-860-001).
(4)
If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002). Then, it is not necessary to open the LGCIU circuit breakers.
(5) If the electrical power is necessary, do the precautions for flight R configuration with electrical power before you open the circuit R breakers (Ref. TASK 32-00-00-860-001).
1EFF : ALL 1 32-31-73Page 503 1 1 Feb 01/05 1 1 1CES 1 Subtask 32-31-73-582-055
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LANDING GEAR 起落架5(56)