FOR FIN 26GA, 27GA, 28GA, 29GA
32-31-73-000-001 32-31-73-400-001 FOR FIN 30GA, 31GA Removal of the Proximity-Sensors 9GA(8GA), 11GA(10GA), 27GA(26GA), 29GA(28GA), 15GA(14GA), 17GA(16GA), 21GA(20GA), 23GA(22GA), 33GA(32GA), 35GA(34GA)Installation of the Proximity-Sensors 9GA(8GA), 11GA(10GA), 27GA(26GA), 29GA(28GA), 15GA(14GA), 17GA(16GA), 21GA(20GA), 23GA(22GA), 33GA(32GA)...
32-31-73-000-005 32-31-73-400-005 Removal of the NLG Proximity-Sensors 12GA, 13GA, 18GA, 19GA, 24GA, 25GA, 30GA, 31GA, 37GA (36GA), 39GA (38GA)Installation of the NLG Proximity-Sensors 12GA, 13GA, 18GA, 19GA, 24GA, 25GA, 30GA, 31GA, 37GA (36GA), 39GA (38GA)
FOR FIN 32GA, 33GA, 34GA, 35GA
32-31-73-000-001 Removal of the Proximity-Sensors 9GA(8GA),
11GA(10GA), 27GA(26GA), 29GA(28GA), 15GA(14GA),
17GA(16GA), 21GA(20GA), 23GA(22GA), 33GA(32GA),
35GA(34GA)
32-31-73-200-001 Inspection of the MLG Proximity Sensor and Target
Clearances
32-31-73-400-001 Installation of the Proximity-Sensors 9GA(8GA),
11GA(10GA), 27GA(26GA), 29GA(28GA), 15GA(14GA),
17GA(16GA), 21GA(20GA), 23GA(22GA), 33GA(32GA)...
32-31-73-820-003 Adjustment of the MLG Door Open Proximity Sensors
32GA, 33GA, 34GA, 35GA
FOR FIN 36GA, 37GA, 38GA, 39GA
1EFF : ALL 1 32-31-73Page A504 1 1 May 01/04R 1 1 1CES 1
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
32-31-73-000-005 Removal of the NLG Proximity-Sensors 12GA, 13GA, 18GA, 19GA, 24GA, 25GA, 30GA, 31GA, 37GA (36GA), 39GA (38GA)
32-31-73-200-002 Inspection of the NLG Proximity Sensor and Target Clearances
32-31-73-400-005 Installation of the NLG Proximity-Sensors 12GA, 13GA, 18GA, 19GA, 24GA, 25GA, 30GA, 31GA, 37GA (36GA), 39GA (38GA)
32-31-73-820-004 Adjustment of the NLG Door Open Proximity Sensors
36GA, 37GA, 38GA, 39GA FOR FIN 12MJ, 5MJ 52-35-13-000-002 Removal of the Proximity Switches 5MJ and/or 12MJ 52-35-13-400-002 Installation of the Proximity Switches 5MJ and 12MJ FOR FIN 28WV, 34WV 52-71-00-820-004 Adjustment of the Proximity Switches 28WV and 34WV of
the Locking Handle of the Cargo Compartment Doors 52-71-12-000-001 Removal of the Proximity Switches 28WV and 34WV 52-71-12-400-001 Installation of the Proximity Switches 28WV and 34WV FOR FIN 30WV, 32WV 52-71-00-820-003 Adjustment of the Proximity Switches 30WV and 32WV of
the Cargo Compartment Door Threshold 52-71-12-000-002 Removal of the Proximity Switches 30WV and 32WV 52-71-12-400-002 Installation of the Proximity Switches 30WV and 32WV
3. Job Set-up
__________
R (Ref. Fig. 513/TASK 32-31-73-991-038, 514/TASK 32-31-73-991-039, 515/TASK 32-31-73-991-040)
Subtask 32-31-73-941-065
A. Safety Precautions
(1)
Put the safety barriers in position.
(2)
Install the ground safety locks on the landing gear (Ref. TASK 32-00-00-481-001).
(3)
On the panel 400VU:
-make sure that the landing-gear control-lever 6GA is in the DOWN position
-put a warning notice in position to tell persons not to operate the landing gear.
1EFF : ALL 1 32-31-73Page A505 1 1 May 01/04 1 1 1CES 1
LGCIU ARINC Tray Connector AA - Proximity Sensor/Switch Pin Locations R Figure 513/TASK 32-31-73-991-038- 12 (SHEET 1)
1EFF : ALL 1 32-31-73Page A506 1 1 May 01/04 1 1 1CES 1
LGCIU ARINC Tray Connector AA - Proximity Sensor/Switch Pin Locations R Figure 513/TASK 32-31-73-991-038- 22 (SHEET 2)
1EFF : ALL 1 32-31-73Page A507 1 1 May 01/04 1 1 1CES 1
R Proximity Sensor/Switch Inductance Check Data - Aircraft On-Ground Condition Figure 514/TASK 32-31-73-991-039- 12 (SHEET 1)
1EFF : ALL 1 32-31-73Page A508 1 1 May 01/05 1 1 1CES 1
R Proximity Sensor/Switch Inductance Check Data - Aircraft On-Ground Condition Figure 514/TASK 32-31-73-991-039- 22 (SHEET 2)
1EFF : ALL 1 32-31-73Page A509 1 1 May 01/05 1 1 1CES 1
R Proximity Sensor/Switch Inductance Check Data - Simulated Flight Condition Figure 515/TASK 32-31-73-991-040- 12 (SHEET 1)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LANDING GEAR 起落架5(84)