32-21-11 15 -03032-21-11 15B-03032-21-11 15C-030 32-21-11 15 -25032-21-11 15B-250 32-21-11 15 -25032-21-11 15B-250 32-21-11 15 -03032-21-11 15B-03032-21-11 15C-030 32-21-11 12 -13032-21-11 12A-13032-21-11 12B-130
1EFF : ALL 1 32-31-73Page 576 1 1 May 01/05 1 1 1CES 1 D. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
07-11-00-581-003
07-11-00-586-001
24-41-00-862-002
29-10-00-864-001 29-23-00-860-001
29-23-00-860-002
32-00-00-481-001
32-00-00-481-002
R R R R 32-00-00-860-001 32-00-00-860-002 32-22-00-010-001 32-22-00-410-001 32-69-00-740-001
32-31-73-991-023 32-31-73-991-025
3. Job Set-up__________
Subtask 32-31-73-941-063
A. Safety Precautions
Lifting of the Aircraft at Forward Jacking Point, MLG Wheels on the GroundLowering of the Aircraft at Forward Jacking Point, MLG Wheels on the GroundDe-energize the Aircraft Electrical Circuits Supplied from the External PowerDepressurize the Green Hydraulic SystemDisconnection of the Isolation Coupling of the Power Transfer Unit (PTU)Connection of the Isolation Coupling of the Power Transfer Unit (PTU)Installation of the Safety Devices on the Landing GearsInstallation of the Safety Devices on the Landing Gear Doors Flight Configuration Precautions with Electrical Power Ground Configuration after Flight Configuration with Electrical PowerNose Gear Doors - Ground Doors OpeningNose Gear Doors - Ground Doors ClosingBITE Check Landing Gear Control Interface Unit (LGCIU) using MCDU to Ensure that Continuous BITE is OperativeFig. 511Fig. 512
(1)
Put the safety barriers in position.
(2)
Make sure that the ground safety locks are installed on the landing gear (Ref. TASK 32-00-00-481-001).
1EFF : ALL 1 32-31-73Page 577 1 1 Nov 01/04 1 1 1CES 1
(3) On the panel 400VU:
-make sure that the landing-gear control-lever 6GA is in the DOWN
position R - put a warning notice in position to tell persons not to operate the R Landing Gear and the NLG doors.
Subtask 32-31-73-860-065
B. Aircraft Maintenance Configuration
(1)
Make sure that the Green hydraulic system is depressurized. (Ref. TASK 29-10-00-864-001).
(2)
Disconnect the isolation coupling of the PTU (Ref. TASK 29-23-00-860-001).
(3)
If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002). Then, it is not necessary to open the LGCIU circuit breakers.
(4)
If the electrical power is necessary, do the precautions for flight configuration (Ref. TASK 32-00-00-860-001) before you open the LGCIU circuit breakers.
Subtask 32-31-73-865-079
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU L/G/LGCIU/SYS1/NORM 1GA C09 121VU HYDRAULIC/LGCIU/SYS2 2GA Q35 121VU HYDRAULIC/LGCIU/SYS1/GRND SPLY 52GA Q34
Subtask 32-31-73-010-060
D. Get Access
(1)
Open the NLG doors (Ref. TASK 32-22-00-010-001).
(2)
Make sure that a SAFETY PIN - NLG DOOR (98D32203502000) is installed in each NLG door (Ref. TASK 32-00-00-481-002).
1EFF : ALL 1 32-31-73Page 578 1 1 May 01/04 1 1 1CES 1 1EFF : ALL 1 32-31-73Page 579 1 1 May 01/04 1 1 1CES 1
4. Procedure_________
Subtask 32-31-73-220-087
A. Dimensional Check
(Ref. Fig. 511/TASK 32-31-73-991-023)
R (1) For (System 1) proximity sensor 24GA:
R
R (a) Make sure that the dimension Z measures 2 mm (0.0787 in.) +/-
R 0.20 mm (0.0078 in.)
R
R (b) Make sure that the dimension X measures 1.35 mm (0.0531 in.) +/-
R 0.75 mm (0.0295 in.).
R (2) For (System 2) proximity sensor 25GA:
R
R (a) Make sure that the dimension X1 measures 1.35 mm (0.0531 in.) +/-
R 0.75 mm (0.0295 in.)