- close the circuit breaker (3WZ).
(a) If this circuit breaker stays closed:
- install the GPWC (Ref. AMM TASK 34-48-34-400-001)
1 If the circuit breaker trips again:
_
- replace the GPWC (Ref. AMM TASK 34-48-34-000-001) and (Ref. AMM TASK 34-48-34-400-001).
(b) If this circuit breaker trips again:
- do a check for a short to ground at the wiring between the circuit breaker (3WZ) and the GPWC (1WZ) (Ref. ASM 34-48/01).
1 If there is a short to ground:
_ - repair the above wiring.
2 If there is no short to ground:
_
- replace the C/B-EIS/GPWS/115VAC (3WZ).
3 Install the GPWC
_ (Ref. AMM TASK 34-48-34-400-001).
D. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-48-00∞∞∞∞∞∞∞∞∞∞Page 202
Feb 01/98 CES Loss of the ECAM Control Panel
1. Possible Causes
_______________
- GPWC (1WZ)
- CTL PNL-ECAM (6WT)
- wiring of the AUDIO SUPPRESSION discrete from the ECAM control panel (6WT) to the GPWC (1WZ)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-61-12-000-001 Removal of the ECAM Control Panel (6WT)
AMM 31-61-12-400-001 Installation of the ECAM Control Panel (6WT)
AMM 34-48-00-740-002 BITE Test of the Enhanced GPWC
AMM 34-48-34-000-001 Removal of the GPWC (1WZ)
AMM 34-48-34-400-001 Installation of the GPWC (1WZ)
ASM 34-48/01
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the Enhanced GPWS (Ref. AMM TASK 34-48-00-740-002).
4. Fault Isolation
_______________
A. If the BITE test gives the maintenance message ECP (6WT)/GPWC (1WZ):
- replace the GPWC (1WZ) (Ref. AMM TASK 34-48-34-000-001) and (Ref. AMM TASK 34-48-34-400-001).
(1) If the fault continues:
- replace the CTL PNL-ECAM (6WT) (Ref. AMM TASK 31-61-12-000-001) and (Ref. AMM TASK 31-61-12-400-001).
(a) If the fault continues:
- do a check and repair the wiring of the AUDIO SUPPRESSION discrete from the ECAM control panel (6WT) to the GPWC (1WZ) (Ref. ASM 34-48/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-48-00∞∞∞∞∞∞∞∞∞∞Page 203
Feb 01/98 CES Loss of the Landing Gear Signal Input
1. Possible Causes
_______________
- GPWC (1WZ)
- LGCIU-1 (5GA1)
- wiring of the LANDING GEAR discrete from the GPWC (1WZ) to the LGCIU1 (5GA1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 32-31-71-000-001 Removal of the LGCIU (5GA1, 5GA2)
AMM 32-31-71-400-001 Installation of the LGCIU (5GA1, 5GA2)
AMM 34-48-00-740-002 BITE Test of the GPWS
AMM 34-48-00-740-002 BITE Test of the Enhanced GPWC
AMM 34-48-34-000-001 Removal of the GPWC (1WZ)
AMM 34-48-34-400-001 Installation of the GPWC (1WZ)
ASM 34-48/01
3. Fault Confirmation
__________________
**ON A/C 001-049, 051-060, 101-104,
A. Test
(1) Do the BITE test of the Enhanced GPWS (Ref. AMM TASK 34-48-00-740-002).
R **ON A/C 061-099, 105-149, 151-199, 201-299, 301-399, 401-499,
A. Test
(1) Do the BITE test of the GPWS (Ref. AMM TASK 34-48-00-740-002).
R **ON A/C ALL
4. Fault Isolation
_______________
A. If the BITE test gives the maintenance message LGCIU (5GA1)/GPWC (1WZ):
- replace the GPWC (1WZ) (Ref. AMM TASK 34-48-34-000-001) and (Ref. AMM TASK 34-48-34-400-001).
(1) If the fault continues:
- replace the LGCIU-1 (5GA1) (Ref. AMM TASK 32-31-71-000-001) and (Ref. AMM TASK 32-31-71-400-001).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 3(67)