- install the DME interrogator 2.
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-51-00∞∞∞∞∞∞∞∞∞∞Page 251
Feb 01/05R CES
Loss of the DME2 Interface with the DMC1
1. Possible Causes
_______________
- DMC-1 (1WT1)
- wiring between the DMC1 and the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-004 EIS System Test
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
AMM 34-51-00-740-002 BITE Test of the DME
ASM 34-51/01
3. Fault Confirmation
__________________
A. Test Do the BITE test of the DME (system 2) (Ref. AMM TASK 34-51-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message DMC2/1
(1WT2/1)/DDRMI(1FN)/DME2(2SD2):
- do the EIS system test (for the DMC1) (Ref. AMM TASK 31-60-00-740-004).
(1) If the test gives a maintenance message related to a DMC1 fault:
- replace the DMC-1 (1WT1) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(2) If the test does not give a maintenance message related to a DMC1 fault:
- remove the DMC1
- do a check and repair the wiring between the DMC1 and the first terminal block: for pins AA/7J, 7K of the DMC1 (Ref. ASM 34-51/01)
- install the DMC1.
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-51-00∞∞∞∞∞∞∞∞∞∞Page 252
Feb 01/05 CES Loss of the DME2 Interface with the DMC2
1. Possible Causes
_______________
- DMC-2 (1WT2)
- wiring between the DMC2 and the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-004 EIS System Test
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
AMM 34-51-00-740-002 BITE Test of the DME
ASM 34-51/01
3. Fault Confirmation
__________________
A. Do the BITE test of the DME (system 2) (Ref. AMM TASK 34-51-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message DMC2/1
(1WT2/1)/DDRMI(1FN)/DME2(2SD2):
- do the EIS system test (for the DMC2) (Ref. AMM TASK 31-60-00-740-004).
(1) If the test gives a maintenance message related to a DMC2 fault:
- replace the DMC-2 (1WT2) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(2) If the test does not give a maintenance message related to a DMC2 fault:
- remove the DMC2
- do a check and repair the wiring between the DMC2 and the first terminal block: for pins AA/7J, 7K of the DMC2 (Ref. ASM 34-51/01)
- install the DMC2.
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-51-00∞∞∞∞∞∞∞∞∞∞Page 253
Feb 01/05 CES TASK 34-51-00-810-833 Display of Incorrect Ground Station Identification Codes on the NDs
1. Possible Causes
_______________
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
34-51-00-810-823 Loss of the DME Antenna 1 Signals 34-51-00-810-828 Loss of the DME Antenna 2 Signals AMM 34-51-00-720-001 Functional Test of the DME
3. Fault Confirmation
__________________
A. Not applicable, you cannot confirm this fault on the ground.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 3(106)