3. Fault Confirmation
__________________
A. Test Do the BITE test of the VOR/MARKER (system 1) (Ref. AMM TASK 34-55-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message DMC1/2 (1WT1/2)/DDRMI (1FN)/VOR1 (3RS1):
- do the SYSTEM TEST of the DMC1 (Ref. AMM TASK 31-60-00-740-004).
(1) If the test gives a maintenance message related to a DMC1 fault:
- replace the DMC-1 (1WT1) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(2) If the test is OK:
- remove the DMC1
- do a check and repair the wiring between the DMC1 and the first terminal block: for pins AA/9C, 9D (Ref. ASM 34-55/01)
- install the DMC1.
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-55-00∞∞∞∞∞∞∞∞∞∞Page 254
Feb 01/05R CES
Erroneous VOR1 (VOR2) Bearing Indications
1. Possible Causes
_______________
- the connectors 40VC or (53VC)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R ESPM 204431 AMM 34-55-00-720-001 Functional Test of the VOR/MKR
R AWM 34-55-03 AWM 34-55-04
3. Fault Confirmation
__________________
A. Do the Functional Test of the VOR/MKR
(Ref. AMM TASK 34-55-00-720-001).
4. Fault Isolation
_______________
A. If the operational test shows an erroneous indications or fluctuations: -Do a check and repair if necessary the connectors 40VC or (53VC). (Ref. AWM 34-55-03) or (Ref. AWM 34-55-04)
R (Ref. ESPM 204431)
B. Do the test given in Para. 3 TASK 34-55-00-810-839 Display of Incorrect Ground Station Identification Codes on the NDs
1. Possible Causes
_______________
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
34-55-00-810-812 Loss of the VOR 1 Data on the ND 34-55-00-810-814 Loss of the VOR 2 Data on the ND AMM 34-55-00-720-001 Functional Test of the VOR/MKR
3. Fault Confirmation
__________________
A. Not applicable, you cannot confirm this fault on the ground.
4. Fault Isolation
_______________
A. If the fault symptom is identified by the crew observation, incorrect identification codes shown on the NDs:
- do the functional test of the VOR/MKR (Ref. AMM TASK 34-55-00-720-001).
(1) If the test is OK:
- no maintenance action is required.
NOTE : The display of incorrect identification codes on the NDs can
____ result from a bad transmission from the ground station.
(2) If the test is not OK:
- refer to the procedure (Ref. TASK 34-55-00-810-812) and (Ref. TASK 34-55-00-810-814) (para. fault isolation only).
RADIO MAGNETIC INFORMATION - SWITCHING AND INDICATING
_____________________________________________________ FAULT ISOLATION PROCEDURES
__________________________
R **ON A/C 001-049, 051-099, 101-105, 151-199,
TASK 34-57-00-810-801
Failure of the VOR/DME RMI
1. Possible Causes
_______________
- RMI-VOR/DME (11FN)
- wiring of the 115VAC signal from the circuit breaker (12FN) to the VOR/DME RMI (11FN)
- wiring of the ground signal at the VOR/DME RMI (11FN)
- C/B - NAV/VOR/DME/RMI (12FN)
- C/B-NAV/VOR/DME/RMI (12FN)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 34-14-00-740-001 Interface Test of the IR
AMM 34-57-22-000-001 Removal of the VOR/DME RMI (11FN)
AMM 34-57-22-400-001 Installation of the VOR/DME RMI (11FN)
ASM 34-57/01
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 3(160)