- RMI-VOR/ADF/DME (21FN)
- wiring between the VOR/DME RMI and the first terminal block
- wiring between the VOR/ADF/DME RMI and the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-51-00-740-002 BITE Test of the DME
AMM 34-57-22-000-001 Removal of the VOR/DME RMI (11FN)
AMM 34-57-22-000-002 Removal of the VOR/ADF/DME RMI (21FN)
AMM 34-57-22-400-001 Installation of the VOR/DME RMI (11FN)
AMM 34-57-22-400-002 Installation of the VOR/ADF/DME RMI (21FN)
ASM 34-51/01
3. Fault Confirmation
__________________
A. Test Do the BITE test of the DME (system 1) (Ref. AMM TASK 34-51-00-740-002).
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-105, 151-199,
A. If the test gives the maintenance message DMC1/2
(1WT1/2)/DDRMI(1FN)/DME1(2SD1):
- replace the RMI-VOR/DME (11FN) (Ref. AMM TASK 34-57-22-000-001) and (Ref. AMM TASK 34-57-22-400-001).
(1) If the fault continues:
- remove the VOR/DME RMI
- do a check and repair the wiring between the VOR/DME RMI and the first terminal block: for pins A/<G, <H of the VOR/DME RMI (Ref. ASM 34-51/01)
- install the VOR/DME RMI.
R **ON A/C 106-149, 201-299, 301-399, 401-499,
A. If the test gives the maintenance message DMC1/2
(1WT1/2)/DDRMI(1FN)/DME1(2SD1):
- replace the RMI-VOR/ADF/DME (21FN) (Ref. AMM TASK 34-57-22-000-002) and (Ref. AMM TASK 34-57-22-400-002).
(1) If the fault continues:
- remove the VOR/ADF/DME RMI
- do a check and repair the wiring between the VOR/ADF/DME RMI and the first terminal block: for pins A/9, 10 of the VOR/ADF/DME RMI (Ref. ASM 34-51/01)
- install the VOR/ADF/DME RMI.
**ON A/C ALL
B. Do the test given in para. 3.
Loss of the DME1 Data
1. Possible Causes
_______________
- INTRG-DME, 1 (2SD1)
- wiring between the DME interrogator 1 and the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 34-51-00-740-002 BITE Test of the DME
AMM 34-51-33-000-001 Removal of the DME Interrogator (2SD1,2SD2)
AMM 34-51-33-400-001 Installation of the DME Interrogator (2SD1,2SD2)
ASM 34-51/01
3. Fault Confirmation
__________________
A. Test Do the BITE test of the DME (system 1) (Ref. AMM TASK 34-51-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message DMC1/2
(1WT1/2)/DDRMI(1FN)/DME1(2SD1):
- swap the INTRG-DME, 1 (2SD1) and the DME interrogator 2 (Ref. AMM TASK 34-51-33-000-001) and (Ref. AMM TASK 34-51-33-400-001).
(1) If the fault stops:
- replace the DME interrogator that you installed on side 2.
(2) If the fault continues:
- remove the DME interrogator 1
- do a check and repair the wiring between the DME interrogator 1 and the first terminal block: for pins AB/3G, 3H of the DME interrogator 1 (Ref. ASM 34-51/01)
- install the DME interrogator 1.
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-51-00∞∞∞∞∞∞∞∞∞∞Page 244
Feb 01/05R CES
Loss of the DME1 Interface with the DMC1
1. Possible Causes
_______________
- DMC-1 (1WT1)
- wiring between the DMC1 and the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-004 EIS System Test
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
AMM 34-51-00-740-002 BITE Test of the DME