EICAS STATUS MESSAGES
None
PLACARD
Electrical system control panel as appropriate - APU GEN INOP (REMOVED) MAINTENANCE (M)
NOTE: If failure is such that APU operation could cause additional generator damage, airplane may be operated with the APU generator removed.
1. Removal of inoperative APU generator:
A. Remove APU generator (Ref. MM 24-21-01).
B. Set nuts on APU mount pad studs so that at least one inch is between nuts and seal plates.
C. Secure the four power leads disconnected from the generator to prevent damage or arcing.
D. Install APU generator dispatch kit on APU mounting pad.
NOTE: APU generator removed dispatch kit, B49006-1, is stowed in the flight dispatch kit in the forward cargo compartment.
E. Pass APU mounting pad studs through keyholes in Generator Cover Box.
F. Rotate Generator Cover Box counter-clockwise to allow studs to move into smaller part of the Generator Cover Box keyholes.
G. Tighten stud nuts to 260-320 pound-inches.
H. Replenish APU oil (AMM 12-22-03).
I. Close APU access door.
2. Verify that the HMG operates normally (Ref. AMM 24-25-00): A. Supply electrical power (AMM 24-22-00/201).
B. Verify that the following circuit breakers on the P11 panel are closed:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 最低设备清单 Minimum Equipment List (MEL) 1(65)