3) Verify message “SINGLE SOURCE” is not displayed at power up. If this message is displayed, AFDS is in a single source configuration and dispatch with autopilot operation is not permitted. Dispatch may be conducted by considering all autopilots inoperative.
2. Autopilot Inoperative, Autopilot Electrohydraulic Servo Valves (EHSV) Leaking:
NOTE: The following procedure is generic for the three Elevator Autopilot Servo (EAS) Electrohydraulic Valves and the three Directional Autopilot Servo (DAS) Electrohydraulic Valves.
A. Remove applicable hydraulic pressure at panel P5.
1) Left EAS/DAS - Left hydraulic system
2) Center EAS/DAS - Center hydraulic system
3) Right EAS/DAS - Right hydraulic system
B. Set panel P61 switches L, C, R TAIL FLT CONTROL SHUTOFF to OFF.
C. Set the two P10 control stand STAB TRIM switches to CUTOUT.
D. Set the Mode Control Panel F/D switches to OFF.
E. Open the following circuit breakers on the P11 panel:
STAB TRIM SHUTOFF L STAB TRIM SHUTOFF R FLT CONTROL SHUTOFF TAIL L, C, R
MODE CONT PNL L, R
FLT CONT CMPTR PWR L, C, R
FLT CONT CMPTR SERV L, C, R
F. Gain access to the leaky EAS/DAS (Autopilot servo).
G. Remove the pressure and return lines from the autopilot servo.
H. Cap autopilot servo ports with BACC14AG6 or BACC14AG6H caps or equivalent, for 3/8 inch tubing, or BACC14AG4 or BACC14AG4H, for 1/4 inch tubing. Some equivalent parts that may be used during this deferral are BACC14AD0x(J, K, S or D) or MS21914-x(J, K, S or T), where “x” is replaced by “6” or “4” for 3/8 inch or 1/4 inch tubing, respectively.