_
- replace all related EXIT MARKERS (Ref. AMM TASK 33-51-13-000-001) and (Ref. AMM TASK 33-51-13-400-001).
a If the fault continues:
_
- do a check and repair the wiring between the: INVERTER (104WL) pin 3 and all related EXIT MARKERS, INVERTER (104WL) pin 4 and all related EXIT MARKERS (Ref. ASM 33-51/04).
(4) If all LIGHTS-EMERGENCY, CABIN and EXIT MARKERS related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- replace the POWER SUPPLY UNIT-EMERGENCY (11WL) (Ref. AMM TASK 33-51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).
(5) If one or more lamps of the SIGNS-EXIT LOCATION or SIGNS-EXIT MARKING related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- replace the lamp(s).
(a) If the fault continues:
- do a check for approx. 6 VDC at the related SIGN-EXIT LOCATION or SIGN-EXIT MARKING (Ref. ASM 33-51/02).
1 If there are approx. 6 VDC:
_
- replace the related SIGN-EXIT LOCATION (Ref. AMM TASK 33-51-17-000-001) and (Ref. AMM TASK 33-51-17-400-001) or SIGN-EXIT MARKING (Ref. AMM TASK 33-51-16-000-001) and (Ref. AMM TASK 33-51-16-400-001).
2 If there are no 6 VDC:
_
- do a check and repair the wiring between the: POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/N or R and the related SIGN-EXIT LOCATION or SIGN-EXIT MARKING, related SIGN-EXIT LOCATION or SIGN-EXIT MARKING and GND (Ref. ASM 33-51/02).
(6) If one or more lamps of the ESCAPE HATCH-HANDLE LIGHTS related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- replace the lamp(s).
(a) If the fault continues:
- do a check for approx. 6 VDC at the related ESCAPE HATCH-HANDLE LIGHT (Ref. ASM 33-51/02).
1 If there are approx. 6 VDC:
_
- replace the related ESCAPE HATCH-HANDLE LIGHT (Ref. AMM TASK 33-51-11-000-001) and (Ref. AMM TASK 33-51-11-400-001).
2 If there are no 6 VDC:
_
- do a check and repair the wiring between the: POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/N or R and the related ESCAPE HATCH-HANDLE LIGHT,
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-107, 109-149, 229-299, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page 230
Aug 01/05 CES related ESCAPE HATCH-HANDLE LIGHT and GND (Ref. ASM 33-51/02).
(7) If all SIGNS-EXIT LOCATION, SIGNS-EXIT MARKING and ESCAPE HATCH-HANDLE LIGHTS related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- replace the POWER SUPPLY UNIT-EMERGENCY (11WL) (Ref. AMM TASK 33-51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).
(a) If the fault continues:
- do a check and repair the wiring between the: POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/<F and the Relay (8WL) connector A/2 (Ref. ASM 33-51/01) and (Ref. ASM 33-51/02).
(8) If all lights, signs and markers related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- replace the POWER SUPPLY UNIT-EMERGENCY (11WL) (Ref. AMM TASK 33-51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).
**ON A/C 159-199, 210-228,
C. If the test gives the maintenance message EPSU INT LOAD EMER L, do the operational test of the emergency cabin lights and signs (Ref. AMM TASK 33-51-00-710-004).
NOTE : The time taken to do this test must not be more than 1 minute to
____ prevent discharge of the emergency lighting batteries.
(1) If one or more lamps of the LIGHTS-EMERGENCY, CABIN related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- replace the lamp(s).
(a) If the fault continues:
- do a check for approx. 6 VDC at the related LIGHT-EMERGENCY, CABIN (Ref. ASM 33-51/02).
1 If there are approx. 6 VDC:
_
- replace the related LIGHT-EMERGENCY, CABIN (Ref. AMM TASK 33-51-11-000-001) and (Ref. AMM TASK 33-51-11-400-001).
2 If there are no 6 VDC:
_
- do a check and repair the wiring between the: POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/E or G and the related LIGHT-EMERGENCY, CABIN, related LIGHT-EMERGENCY, CABIN and GND (Ref. ASM 33-51/02).