B. If there is no CFDS maintenance message, but one light does not come on:
- replace the related FLUORESCENT TUBE (Ref. AMM TASK 33-21-11-000-001) and (Ref. AMM TASK 33-21-11-400-001).
(1) If the fault continues:
- do a check for 115 VAC at the related BALLAST UNIT connector A/C (Ref. ASM 33-21/01), (Ref. ASM 33-21/02) and (Ref. ASM 33-21/03).
(a) If there is approx. 115 VAC:
- replace the related BALLAST UNIT-LAMP (Ref. AMM TASK 33-21-11-000-001) and (Ref. AMM TASK 33-21-11-400-001).
(b) If there is no 115 VAC:
- do a check and repair the wiring if necessary between the related: BALLAST UNIT connector A/C and its CB, BALLAST UNIT connector A/A and GND, BALLAST UNIT connector A/B and GND (Ref. ASM 33-21/01), (Ref. ASM 33-21/02) and (Ref. ASM 33-21/03).
(2) If the fault continues:
- replace the related DEU-A (Ref. AMM TASK 23-73-46-000-001) and (Ref. AMM TASK 23-73-46-400-001).
(3) If the fault continues:
- do a check and repair the wiring between the related: BALLAST UNIT connector A/D and DEU-A connector B/1,B/4,B/9 or B/12, BALLAST UNIT connector A/E and DEU-A connector B/2,B/5,B/10 or B/13, BALLAST UNIT connector A/F and DEU-A connector B/3,B/6,B/11 or B/14 (Ref. ASM 33-21/01), (Ref. ASM 33-21/02) and (Ref. ASM 33-21/03).
C. Do the test as given in the Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-21-00∞∞∞∞∞∞∞∞∞∞Page 202
May 01/05R
CES
TASK 33-21-00-810-802
Cabin Lights - Two thru Four Cabin Lights in Series at one Cabin Side do not come on
1. Possible Causes
_______________
- FLUORESCENT TUBE
- DEU-A
- BALLAST UNIT-LAMP
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-003 BITE Test of the Cabin Intercommunication Data System
(CIDS) through the PTP AMM 23-73-46-000-001 Removal of the Decoder/Encoder Unit (DEU) A 200RH AMM 23-73-46-400-001 Installation of the Decoder/Encoder Unit (DEU) A
200RH
AMM 33-21-00-710-001 Operational Test of the General Illumination
AMM 33-21-11-000-001 Removal of the Ballast Unit and Lampholder 1LG1
(3LG1) AMM 33-21-11-400-001 Installation of the Ballast Unit and Lampholder 1LG1 ASM 33-21/01 ASM 33-21/02 ASM 33-21/03
3. Fault Confirmation
__________________
A. Do the CIDS BITE test (Ref. AMM TASK 23-73-00-740-003)
B. Do the operational test of the general illumination (Ref. AMM TASK 33-21-00-710-001).
4. Fault Isolation
_______________
R
R A. If the test gives a maintenance message, do the trouble shooting R procedure related to the maintenance message.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-21-00∞∞∞∞∞∞∞∞∞∞Page 203
May 01/05 CES
B. If there is no CFDS message but between 2 and 4 FLUORESCENT TUBES in series at one cabin side do not come on:
- change a FLUORESCENT TUBE
(1) If the FLUORESCENT TUBE comes on:
- replace all the FLUORESCENT TUBES
(2) If the fault continues:
- replace the related DEU-A (Ref. AMM TASK 23-73-46-000-001) and (Ref. AMM TASK 23-73-46-400-001).
(3) If the fault continues:
- do a check for 115 VAC at the related BALLAST UNIT connector A/C (Ref. ASM 33-21/01), (Ref. ASM 33-21/02) and (Ref. ASM 33-21/03).
(a) If there is approx. 115 VAC:
- replace the related BALLAST UNIT-LAMP (Ref. AMM TASK 33-21-11-000-001) and (Ref. AMM TASK 33-21-11-400-001). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 LIGHTS 灯光(36)