• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 22:45来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 - remove the ESCAPE SLIDE OFFWING L (7504MM) as necessary to get access to the electrical connector (Ref. AMM TASK 25-62-42-000-001).

 - connect a serviceable escape slide with the adapter cable to the aircraft.

 - do the operational test of the emergency lights not with CIDS (Ref. AMM TASK 33-51-00-710-006).


 1 If the fault does no longer exist:
_
 - remove the old ESCAPE SLIDE OFFWING L (7504MM) fully (Ref. AMM TASK 25-62-42-000-001).

 - install the serviceable escape slide (Ref. AMM TASK 25-62-42-400-001).


 2 If the fault continues:
_
 - do a check and repair the wiring between: escape slide connector 7531VC pin A and EPSU (11WL) pin T,
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page 260
 201-299, May 01/05 CES


 escape slide connector 7531VC pin B and GND,
 LIGHT-FWD EMER, OVERWING (61WL) connector A/B and EPSU
 (11WL) pin T,
 LIGHT-FWD EMER, OVERWING (61WL) connector A/A and GND,
 LIGHT-FWD EMER, OVERWING (61WL) connector A/C and GND,
 LIGHT-AFT EMER, OVERWING (63WL) connector A/B and EPSU
 (11WL) pin F,
 LIGHT-AFT EMER, OVERWING (63WL) connector A/A and GND,
 LIGHT-AFT EMER, OVERWING (63WL) connector A/C and GND,
 PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE (6WN1) pin E and
 EPSU (11WL) pin S,
 PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE (6WN1) pin F and
 GND,
 PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1) pin E and EPSU
 (11WL) pin <K,
 PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1) pin F and GND,
 PROX SW-HANDLE, L FWD EMER EXIT ESC SLIDE (5WN1) pin E and
 EPSU (11WL) pin C,
 PROX SW-HANDLE, L FWD EMER EXIT ESC SLIDE (5WN1) pin F and
 GND,
 PROX SW-HANDLE FLAP, L FWD EMER EXIT (19WV1) pin E and EPSU
 (11WL) pin D,
 PROX SW-HANDLE FLAP, L FWD EMER EXIT (19WV1) pin F and GND
 (Ref. ASM 33-51/02) and (Ref. AWM 33-51-04).

 - install the old ESCAPE SLIDE OFFWING L (7504MM) (Ref. AMM TASK 25-62-42-400-001).
 3 If the fault continues:
_
 - replace the PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE (6WN1) (Ref. AMM TASK 52-73-11-000-004) and (Ref. AMM TASK 52-73-11-400-004).
 4 If the fault continues:
_
 - replace the PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1) (Ref. AMM TASK 52-71-13-000-001) and (Ref. AMM TASK 52-71-13-400-001).
 5 If the fault continues:
_
 - replace the PROX SW-HANDLE, L FWD EMER EXIT ESC SLIDE (5WN1) (Ref. AMM TASK 52-73-11-000-003) and (Ref. AMM TASK 52-73-11-400-003).
 6 If the fault continues:
_
 - replace the PROX SW-HANDLE FLAP, L FWD EMER EXIT (19WV1) (Ref. AMM TASK 52-71-13-000-001) and (Ref. AMM TASK 52-71-13-400-001).
 (c) If all lamps of the LIGHT-FWD EMER, OVERWING (61WL) and the LIGHT-AFT EMER, OVERWING (63WL) come on and no correct adapter cable between the escape slide and the aircraft electrical connector is available:
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-003, 051-052, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page 261
 May 01/05 CES


 - remove the ESCAPE SLIDE OFFWING L (7504MM) (Ref. AMM TASK 25-62-42-000-001).

 - connect a serviceable escape slide electrically only.

 - do the operational test of the emergency lights not with CIDS (Ref. AMM TASK 33-51-00-710-006).


 1 If the fault does no longer exist:
_
 - install the serviceable escape slide (Ref. AMM TASK 25-62-42-400-001).
 2 If the fault continues:
_
 - do a check and repair the wiring between: escape slide connector 7531VC pin A and EPSU (11WL) pin T, escape slide connector 7531VC pin B and GND, LIGHT-FWD EMER, OVERWING (61WL) connector A/B and EPSU (11WL) pin T, LIGHT-FWD EMER, OVERWING (61WL) connector A/A and GND, LIGHT-FWD EMER, OVERWING (61WL) connector A/C and GND, LIGHT-AFT EMER, OVERWING (63WL) connector A/B and EPSU (11WL) pin F, LIGHT-AFT EMER, OVERWING (63WL) connector A/A and GND, LIGHT-AFT EMER, OVERWING (63WL) connector A/C and GND, PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE (6WN1) pin E and EPSU (11WL) pin S, PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE (6WN1) pin F and GND, PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1) pin E and EPSU (11WL) pin <K, PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1) pin F and GND, PROX SW-HANDLE, L FWD EMER EXIT ESC SLIDE (5WN1) pin E and EPSU (11WL) pin C, PROX SW-HANDLE, L FWD EMER EXIT ESC SLIDE (5WN1) pin F and GND, PROX SW-HANDLE FLAP, L FWD EMER EXIT (19WV1) pin E and EPSU (11WL) pin D, PROX SW-HANDLE FLAP, L FWD EMER EXIT (19WV1) pin F and GND (Ref. ASM 33-51/02) and (Ref. AWM 33-51-04).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 LIGHTS 灯光(103)