(1) If there is approx. 115 VAC:
- replace the related READING-LIGHT POWER UNIT (Ref. AMM TASK 23-73-38-000-001) and (Ref. AMM TASK 23-73-38-400-001).
(2) If there is no 115 VAC:
- do a check and repair the wiring between the related: READING-LIGHT POWER UNIT conn. A/A and RELAY 8LW conn. A2, READING-LIGHT POWER UNIT conn. A/A and RELAY 8LW conn. B2, READING-LIGHT POWER UNIT conn. A/A and RELAY 8LW conn. C2, READING-LIGHT POWER UNIT conn. A/B and GND (Ref. ASM 23-73/13) and (Ref. ASM 33-25/01).
D. If the operational test gives two or more maintenance messages POWER PCB XX R (XX seat row) and all reading lights in two or more right side PSIUs in series do not come on:
- do a check of the RELAY 7LW and replace it if necessary.
(1) If the fault continues:
- do a check and repair the wiring between the: CB 1LW and RELAY 7LW conn. A1, CB 2LW and RELAY 7LW conn. B1, CB 3LW and RELAY 7LW conn. C1, RELAY 7LW conn. A2 and READING-LIGHT POWER UNIT conn. D, RELAY 7LW conn. B2 and READING-LIGHT POWER UNIT conn. D, RELAY 7LW conn. C2 and READING-LIGHT POWER UNIT conn. D (Ref. ASM 23-73/13) and (Ref. ASM 33-25/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-25-00∞∞∞∞∞∞∞∞∞∞Page 206
May 01/05R
CES
E. If the operational test gives two or more maintenance messages POWER PCB XX L (XX seat row) and all reading lights in two or more left side PSIUs in series do not come on:
- do a check of the RELAY 8LW and replace it if necessary.
(1) If the fault continues:
- do a check and repair the wiring between the: CB 4LW and RELAY 8LW conn. A1, CB 5LW and RELAY 8LW conn. B1, CB 6LW and RELAY 8LW conn. C1, RELAY 8LW conn. A2 and READING-LIGHT POWER UNIT conn. D, RELAY 8LW conn. B2 and READING-LIGHT POWER UNIT conn. D, RELAY 8LW conn. C2 and READING-LIGHT POWER UNIT conn. D (Ref. ASM 23-73/13) and (Ref. ASM 33-25/01).
F. If the operational test gives the maintenance message POWER PCB XX L, R and all reading lights come on:
- replace the related DEU-A (Ref. AMM TASK 23-73-46-000-001) and (Ref. AMM TASK 23-73-46-400-001).
G. Do the test given in Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-25-00∞∞∞∞∞∞∞∞∞∞Page 207
May 01/05R
CES PASSENGER READING LIGHTS - TASK SUPPORTING DATA
_______________________________________________
1. System Description
__________________
**ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
(Ref. Fig. 301)
**ON A/C 301-399,
(Ref. Fig. 301A)
R **ON A/C 401-499,
R (Ref. Fig. 301B)
**ON A/C ALL
The passenger reading lights supply high intensity light to each passenger seat. Each light has an ON/OFF switch. The passenger reading lights are installed in the combi-panels. The combi-panels are fitted in the Passenger Service Unit (PSU) channel above the passenger seats. The number of combi-panels on each side of the cabin must agree with the number of seat rows. 115VAC is supplied to the reading lights from the busbars 110XP and 210XP. This is controlled through the cicuit breakers 1LW thru 6LW and the relays 7LW and 8LW. Power units change the 115VAC to 6VAC for the light operation. A fuse in each line gives protection for the transformer and the related Printed Circuit Board (PCB). A switch POWER READ on the Forward Attendant Panel (FAP) 120RH controls the power supply for the reading lights.
Passenger Reading Lights - Schematic Figure 301 (SHEET 1)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞33-25-00∞∞∞∞∞∞∞∞∞∞Page 302
201-299, May 01/05 CES
Passenger Reading Lights - Schematic Figure 301 (SHEET 2)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞33-25-00∞∞∞∞∞∞∞∞∞∞Page 303
201-299, May 01/05 CES
R Passenger Reading Lights - Schematic R Figure 301A
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 301-399, ∞∞33-25-00∞∞∞∞∞∞∞∞∞∞Page 304