 - install the old ESCAPE SLIDE OFFWING L (7504MM) (Ref. AMM TASK 25-62-42-400-001).


 3 If the fault continues:
_
 - replace the PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE (6WN1) (Ref. AMM TASK 52-73-11-000-004) and (Ref. AMM TASK 52-73-11-400-004).
 4 If the fault continues:
_
 - replace the PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1) (Ref. AMM TASK 52-71-13-000-001) and (Ref. AMM TASK 52-71-13-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 151-199, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page 273
 May 01/05 CES


 (c) If all lamps of the LIGHT-FWD EMER, OVERWING (61WL) and the LIGHT-AFT EMER, OVERWING (63WL) come on and no correct adapter cable between the escape slide and the aircraft electrical connector is available:
 - remove the ESCAPE SLIDE OFFWING L (7504MM) (Ref. AMM TASK 25-62-42-000-001).

 - connect a serviceable escape slide electrically only.

 - do the operational test of the emergency lights not with CIDS (Ref. AMM TASK 33-51-00-710-006).


 1_ If the fault does no longer exist:
 - install the serviceable escape slide (Ref. AMM TASK 25-62-
42-400-001).
 2_ If the fault continues:
 - do a check and repair the wiring between:
 escape slide connector 7531VC pin A and EPSU (11WL) pin T,
 escape slide connector 7531VC pin B and GND,
 LIGHT-FWD EMER, OVERWING (61WL) connector A/B and EPSU
 (11WL) pin T,
 LIGHT-FWD EMER, OVERWING (61WL) connector A/A and GND,
 LIGHT-FWD EMER, OVERWING (61WL) connector A/C and GND,
 LIGHT-AFT EMER, OVERWING (63WL) connector A/B and EPSU
 (11WL) pin F,
 LIGHT-AFT EMER, OVERWING (63WL) connector A/A and GND,
 LIGHT-AFT EMER, OVERWING (63WL) connector A/C and GND,
 PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE (6WN1) pin E and
 EPSU (11WL) pin S,
 PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE (6WN1) pin F and
 GND,
 PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1) pin E and EPSU
 (11WL) pin <K,
 PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1) pin F and GND
 (Ref. ASM 33-51/02) and (Ref. AWM 33-51-04).
 - install the removed ESCAPE SLIDE OFFWING L (7504MM) again
 (Ref. AMM TASK 25-62-42-400-001).
 3_ If the fault continues:
 - replace the PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE (6WN1)
 (Ref. AMM TASK 52-73-11-000-004) and (Ref. AMM TASK 52-73-
11-400-004).
 4_ If the fault continues:
 - replace the PROX SW-HANDLE FLAP, L AFT EMER EXIT (21WV1)
 (Ref. AMM TASK 52-71-13-000-001) and (Ref. AMM TASK 52-71-
13-400-001).

 

 D. If the operational test gives the maintenance message
 EPSU EXT LOAD EMER R:

 - do the operational test of the emergency lights not with CIDS (Ref. AMM TASK 33-51-00-710-006).
 (1) If the green LED 'SYSTEM OK' comes on:

 - replace the POWER SUPPLY UNIT-EMERGENCY (12WL) (Ref. AMM TASK 33-51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).

 (2) If the red LED 'EXTERIOR LIGHTS FAULT' comes on, do the test of the right escape-hatch switches of the emergency-exit escape-slide lighting (Ref. AMM TASK 33-51-00-720-001).


 (a) If one or more lamps of the LIGHT-FWD EMER, OVERWING (60WL) and the LIGHT-AFT EMER, OVERWING (62WL) do not come on:
 - replace the lamp(s) (Ref. AMM TASK 33-51-15-000-001) and (Ref. AMM TASK 33-51-15-400-001).
 1 If the fault continues:
_
 - replace the related LIGHT-FWD EMER, OVERWING (60WL) and/or LIGHT-AFT EMER, OVERWING (62WL) (Ref. AMM TASK 33-51-15-000-001) and (Ref. AMM TASK 33-51-15-400-001).
 (b) If all lamps of the LIGHT-FWD EMER, OVERWING (60WL) and the LIGHT-AFT EMER, OVERWING (62WL) come on and a correct adapter cable between the escape slide and the aircraft electrical connector is available:
 - remove the ESCAPE SLIDE OFFWING R (7505MM) as necessary to get access to the electrical connector (Ref. AMM TASK 25-62-42-000-001).

 - connect a serviceable escape slide with the adapter cable to the aircraft.

 - do the operational test of the emergency lights not with CIDS (Ref. AMM TASK 33-51-00-710-006).


 1 If the fault does no longer exist:
_
 - remove the old ESCAPE SLIDE OFFWING R (7505MM) fully (Ref. AMM TASK 25-62-42-000-001).

 - install the serviceable escape slide (Ref. AMM TASK 25-62-42-400-001).


 2 If the fault continues:
_
 - do a check and repair the wiring between: escape slide connector 7532VC pin A and EPSU (12WL) pin T, escape slide connector 7532VC pin B and GND, LIGHT-FWD EMER, OVERWING (60WL) connector A/B and EPSU (12WL) pin T, LIGHT-FWD EMER, OVERWING (60WL) connector A/A and GND, LIGHT-FWD EMER, OVERWING (60WL) connector A/C and GND, LIGHT-AFT EMER, OVERWING (62WL) connector A/B and EPSU (12WL) pin F, LIGHT-AFT EMER, OVERWING (62WL) connector A/A and GND,
 