3. Fault Confirmation
__________________
A. Test Do the operational test of the general illumination (Ref. AMM TASK 33-12-00-710-001).
NOTE : Do this test for the instrument lighting, the supplementary
____ reading lights, the map table lights and the center pedestal light only.
4. Fault Isolation
_______________
A. If, during the operational test:
(1) The dimming function of the F/O map table light rheostat is not operative:
- replace the RHEOSTAT-MAP TABLE LIGHT, F/O (40LE) (Ref. IPC 331201).
(2) The F/O map table light does not come on:
- make sure that there is 28VDC at the F/O map table light rheostat (40LE) pin A (Ref. ASM 33-12/01).
(a) If there is 28VDC:
- replace the LIGHT-MAP TABLE, F/O (42LE) (Ref. IPC 331201). 1 If the fault continues:
_
- repair the wiring between the F/O map table light (42LE) and the related rheostat (40LE) (Ref. ASM 33-12/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-12-00∞∞∞∞∞∞∞∞∞∞Page 227
Feb 01/98 CES (b) If there is no 28VDC:
- replace the RHEOSTAT-MAP TABLE LIGHT, F/O (40LE) (Ref. IPC 331201).
1_ If the fault continues:
- do a check of the wiring from the F/O map table light
rheostat (40LE) pin 1 to the first terminal block (Ref. ASM
33-12/01).
a If the fault continues:
_
- repair the wiring from the F/O map table light rheostat (40LE) pin 2 to the ground terminal block (Ref. ASM 33-12/01).
B. Do the test given in Para. 3.
INSTRUMENT AND PANEL INTEGRAL LIGHTING - FAULT ISOLATION PROCEDURES
___________________________________________________________________
TASK 33-13-00-810-801
Failure at the Pedestal and Main Panel Integral Lighting
1. Possible Causes
_______________
- CONTROLLER-LIGHTING (16LF)
- PLATE-INT LIGHTED IDENT
- wiring
- POT-INTEG LT/MAIN PNL & PED (17LF)
- C/B-LIGHTING/INST LT/MAIN INST/PNL AND/PED (4LF)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
IPC 275143 IPC 331308 AMM 33-13-00-710-001 Operational Test of the Instrument and Panel Integral
Lighting AMM 33-13-51-000-001 Removal of the Lighting Controller (6LF, 16LF, 30LF) AMM 33-13-51-400-001 Installation of the Lighting Controller (6LF, 16LF,
30LF)
ASM 33-13/01
33-13-00-991-004 Fig. 201
33-13-00-991-001 Fig. 202
3. Fault Confirmation
__________________
A. Test Do the operational test of the instrument and panel integral lighting (Ref. AMM TASK 33-13-00-710-001). (Ref. Fig. 201/TASK 33-13-00-991-004)
NOTE : Do this test for the pedestal and main panel integral lighting
____
only.
4. Fault Isolation
_______________
A. If, during the operational test, when you turn the INTEG LT/MAIN PNL & PED potentiometer (17LF) from OFF to BRT:
(1) One light of the related integrally lighted panels is inoperative:
- remove the defective lamp or LED in the PLATE-INT LIGHTED IDENT (Ref. IPC 331308) or (Ref. IPC 275143)
- make sure that there is a voltage at the lamp socket.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-13-00∞∞∞∞∞∞∞∞∞∞Page 201
Feb 01/98 CES
Instrument and Panel Integral Lighting
Figure 201/TASK 33-13-00-991-004
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-13-00∞∞∞∞∞∞∞∞∞∞Page 202
Feb 01/98 CES
(a) If there is a voltage:
- replace the defective lamp.
(b) If there is no voltage:
- do a check and repair the wiring (Ref. ASM 33-13/01).
(2) If the integral lighting of several instruments and/or panels is inoperative:
- do a check of the lighting controller fuse related to the defective lighting circuit (Ref. ASM 33-13/01).
(a) If the fuse is correct: