• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 22:45来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 - EMERGENCY EXIT LOCATION SIGN (51WL)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 33-51-00-710-007 Operational Test of the Emergency Lighting in the
 Cabin by 'LIGHT EMER' Pushbutton Switch AMM 33-51-00-710-010 Operational Test of the Emergency Lights via MCDU AMM 33-51-11-000-001 Removal of the Cabin Emergency Lights AMM 33-51-11-400-001 Installation of the Cabin Emergency Light AMM 33-51-16-000-001 Removal of the Emergency Exit Sign AMM 33-51-16-400-001 Installation of the Emergency Exit Sign AMM 33-51-17-000-001 Removal of the Emergency Exit Location-Sign AMM 33-51-17-400-001 Installation of the Emergency Exit Location-Sign ASM 33-51/02
 3. Fault Confirmation
__________________
 A. Do the operational test of the emergency lights via MCDU (Ref. AMM TASK 33-51-00-710-010).
 4. Fault Isolation
_______________
 A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
 B. If the operational test gives the maintenance message:
 (1) EXIT SIGNS/EPSU(11WL)EMER L:
 - do the Operational Test of the Emergency Lighting in the Cabin by Pushbutton Switch (Ref. AMM TASK 33-51-00-710-007).

 - during the test monitor the EMERGENCY EXIT SIGN (43WL), ESCAPE HATCH-HANDLE LIGHT (70WL1) and the EMERGENCY EXIT LOCATION SIGN (51WL) in the CTR section of the cabin.

 - replace the EMERGENCY EXIT SIGN (43WL) (Ref. AMM TASK 33-51-16-000-001) and (Ref. AMM TASK 33-51-16-400-001) if not illuminated.


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page A239
 Aug 01/05 CES


 - replace the ESCAPE HATCH-HANDLE LIGHT (70WL1) (Ref. AMM TASK 33-51-11-000-001) and (Ref. AMM TASK 33-51-11-400-001) if not illuminated.

 - replace the EMERGENCY EXIT LOCATION SIGN (51WL) (Ref. AMM TASK 33-51-17-000-001) and (Ref. AMM TASK 33-51-17-400-001) if not illuminated.


 (a) If the fault continues:
 - do a check and repair the wiring between: EPSU pin N and the ESCAPE HATCH-HANDLE LIGHT (70WL1) pin 3. EPSU pin N and the EMERGENCY EXIT LOCATION SIGN (51WL) pin 3. EPSU pin R and the EMERGENCY EXIT SIGN (43WL) pin 3. ESCAPE HATCH-HANDLE LIGHT (70WL1) pin 1 and GND. EMERGENCY EXIT LOCATION SIGN (51WL) pin 1 and GND. EMERGENCY EXIT SIGN (43WL) pin 1 and GND (Ref. ASM 33-51/02).
 C. Do the test given in para. 3.
 5. Close-up
________
 A. Put the aircraft back to its initial configuration.

 TASK 33-51-00-810-838


 Failure of the Exit Signs controlled by EPSU 12WL
 1. Possible Causes
_______________
 - EMERGENCY EXIT SIGN (42WL)

 - ESCAPE HATCH-HANDLE LIGHT (70WL2)

 - EMERGENCY EXIT LOCATION SIGN (53WL)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 33-51-00-710-007 Operational Test of the Emergency Lighting in the
 Cabin by 'LIGHT EMER' Pushbutton Switch AMM 33-51-00-710-010 Operational Test of the Emergency Lights via MCDU AMM 33-51-11-000-001 Removal of the Cabin Emergency Lights AMM 33-51-11-400-001 Installation of the Cabin Emergency Light AMM 33-51-16-000-001 Removal of the Emergency Exit Sign AMM 33-51-16-400-001 Installation of the Emergency Exit Sign AMM 33-51-17-000-001 Removal of the Emergency Exit Location-Sign AMM 33-51-17-400-001 Installation of the Emergency Exit Location-Sign ASM 33-51/02
 3. Fault Confirmation
__________________
 A. Do the operational test of the emergency lights via MCDU (Ref. AMM TASK 33-51-00-710-010).
 4. Fault Isolation
_______________
 A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
 B. If the operational test gives the maintenance message:
 (1) EXIT SIGNS/EPSU(12WL)EMER R:
 - do the Operational Test of the Emergency Lighting in the Cabin by Pushbutton Switch (Ref. AMM TASK 33-51-00-710-007).

 - during the test monitor the EMERGENCY EXIT SIGN (42WL), ESCAPE HATCH-HANDLE LIGHT (70WL2) and the EMERGENCY EXIT LOCATION SIGN (53WL) in the CTR section of the cabin.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 LIGHTS 灯光(132)