「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-158, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page 227
201-209, May 01/05 CES
1 If there are approx. 6 VDC:
_
- replace the related ESCAPE HATCH-HANDLE LIGHT (Ref. AMM TASK 33-51-11-000-001) and (Ref. AMM TASK 33-51-11-400-001).
2 If there are no 6 VDC:
_
- do a check and repair the wiring between the: POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/N or R and the related ESCAPE HATCH-HANDLE LIGHT, related ESCAPE HATCH-HANDLE LIGHT and GND (Ref. ASM 33-51/02).
(5) If all SIGNS-EXIT LOCATION, SIGNS-EXIT MARKING and ESCAPE HATCH-HANDLE LIGHTS related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- replace the POWER SUPPLY UNIT-EMERGENCY (11WL) (Ref. AMM TASK 33-51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).
(a) If the fault continues:
- do a check and repair the wiring between the: POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/<F and the Relay (8WL) connector A/2 (Ref. ASM 33-51/01) and (Ref. ASM 33-51/02).
(6) If all lights and signs related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- replace the POWER SUPPLY UNIT-EMERGENCY (11WL) (Ref. AMM TASK 33-51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).
R **ON A/C 106-107, 109-149, 229-299,
C. If the test gives the maintenance message EPSU INT LOAD EMER L, do the operational test of the emergency cabin lights and signs (Ref. AMM TASK 33-51-00-710-004).
NOTE : The time taken to do this test must not be more than 1 minute to
____ prevent discharge of the emergency lighting batteries.
(1) If one or more lamps of the LIGHTS-EMERGENCY, CABIN related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- replace the lamp(s).
(a) If the fault continues:
- do a check for approx. 6 VDC at the related LIGHT-EMERGENCY, CABIN (Ref. ASM 33-51/02).
1 If there are approx. 6 VDC:
_
- replace the related LIGHT-EMERGENCY, CABIN (Ref. AMM TASK 33-51-11-000-001) and (Ref. AMM TASK 33-51-11-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-107, 109-149, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page 228
151-158, 201-209, 229-299, Aug 01/05 CES 2 If there are no 6 VDC:
_
- do a check and repair the wiring between the: POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/E or G and the related LIGHT-EMERGENCY, CABIN, related LIGHT-EMERGENCY, CABIN and GND (Ref. ASM 33-51/02).
(2) If one EXIT MARKER related to the POWER SUPPLY UNIT-EMERGENCY (11WL) does not come on:
- replace the related EXIT MARKER (Ref. AMM TASK 33-51-13-000-001) and (Ref. AMM TASK 33-51-13-400-001).
(a) If the fault continues:
- do a check and repair the wiring between the: INVERTER (104WL) pin 3 and the related EXIT MARKER, INVERTER (104WL) pin 4 and the related EXIT MARKER (Ref. ASM 33-51/04).
(3) If all EXIT MARKERS related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
- do a check for approx. 6 VDC and at the INVERTER (104WL) pin 1 (Ref. ASM 33-51/04):
(a) If there are no 6 VDC:
- do a check for approx. 6 VDC at the POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/G (Ref. ASM 33-51/02).
1 If there are no 6 VDC:
_
- replace the POWER SUPPLY UNIT-EMERGENCY (11WL) (Ref. AMM TASK 33-51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).
2 If there are approx. 6 VDC:
_
- do a check and repair the wiring between the: POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/G and the CAPACITOR (2007VU2) connector A/5, CAPACITOR (2007VU2) connector A/4 and the INVERTER (104WL) pin 1 (Ref. ASM 33-51/02) and (Ref. ASM 33-51/04).
a If the fault continues:
_
- replace the CAPACITOR (2007VU2) (Ref. AMM TASK 33-51-36-000-001) and (Ref. AMM TASK 33-51-36-400-001).
(b) If there are approx. 6 VDC:
- do a check for approx. 115 VAC at the INVERTER (104WL) between pin 3 and 4 (Ref. ASM 33-51/04).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 LIGHTS 灯光(87)