121RH
AMM 33-24-00-710-001 Operational Test of the Lavatory Lighting LQ
ASM 33-24/01
3. Fault Confirmation
__________________
A. Do the operational test of the lavatory lighting (Ref. AMM TASK 33-24-00-710-001)
4. Fault Isolation
_______________
A. If the test confirms the fault:
- do a check of the LAVATORY LIGHTING-RELAY (2LQ) and replace it if necessary.
(1) If the fault continues:
- replace the ATTENDANT PANEL-FORWARD (120RH) (Ref. AMM TASK 23-73-12-000-001) and (Ref. AMM TASK 23-73-12-400-001).
(2) If the fault continues:
- do a check and repair the wiring if necessary between: LAVATORY LIGHTING RELAY 2LQ connector A/X1 and FWD ATTENDANT PANEL (120RH) connector A/14, LAVATORY LIGHTING RELAY 2LQ connector A/A2 and CB 1LQ, LAVATORY LIGHTING RELAY 2LQ connector A/X2 and GND (Ref. ASM 33-24/01).
(3) If the fault continues:
- do the trouble shooting procedures for the FWD ATTENDANT PANEL (120RH) (Ref. TASK 23-73-00-810-838).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-24-00∞∞∞∞∞∞∞∞∞∞Page 203
Feb 01/98 CES
B. Do the test as given in the Para. 3.A .
5. Close-up
________
A. Put the aircraft back to its initial configuration.
TASK 33-24-00-810-803
Lavatory Lighting - In one Lavatory the Lavatory Light cannot be dimmed
1. Possible Causes
_______________
- LAV OCCPD SWITCH
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
33-26-00-810-802 Lavatory Signs - The Occupied or Unoccupied Symbol in the Lavatory Lighted Sign does not come on AMM 33-21-11-000-001 Removal of the Ballast Unit and Lampholder 1LG1
(3LG1) AMM 33-21-11-400-001 Installation of the Ballast Unit and Lampholder 1LG1 AMM 33-24-00-710-001 Operational Test of the Lavatory Lighting LQ AMM 33-26-11-000-001 Removal of the Lavatory Door Microswitch (WJ) AMM 33-26-11-400-001 Installation of the Lavatory Door Microswitch (WJ) ASM 33-24/01 ASM 33-26/01
3. Fault Confirmation
__________________
A. Do the operational test of the lavatory lighting (Ref. AMM TASK 33-24-00-710-001).
4. Fault Isolation
_______________
A. If the test confirms the fault:
- adjust the position of the related LAV OCCPD SWITCH in the door frame of the lavatory (Ref. AMM TASK 33-26-11-400-001).
(1) If the fault continues:
- do a check of the related LAV OCCPD SWITCH and replace it if necessary (Ref. AMM TASK 33-26-11-000-001) and (Ref. AMM TASK 33-26-11-400-001).
(2) If the fault continues:
- replace the related BALLAST UNIT (Ref. AMM TASK 33-21-11-000-001) and (Ref. AMM TASK 33-21-11-400-001).
(3) If the fault continues:
- do a check and repair the wiring if necessary between the related: BALAST UNIT pin D and the LAV OCCPD SWITCH pin NF (Ref. ASM 33-24/01) and (Ref. ASM 33-26/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-24-00∞∞∞∞∞∞∞∞∞∞Page 205
Feb 01/98 CES (4) If the fault continues:
- do the trouble shooting procedures for the related LAV OCCPD SWITCH (Ref. TASK 33-26-00-810-802).
B. Do the test as given in the Para. 3.A .
5. Close-up
________
A. Put the aircraft back to its initial configuration.
LAVATORY LIGHTING - TASK SUPPORTING DATA
________________________________________
Lavatory Lighting - Schematic
Figure 301
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞33-24-00∞∞∞∞∞∞∞∞∞∞Page 302
201-299, May 01/05 CES
R Lavatory Lighting - Schematic R Figure 301A
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 301-399, ∞∞33-24-00∞∞∞∞∞∞∞∞∞∞Page 303
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 LIGHTS 灯光(42)