TASK 33-21-00-810-805
Lighting - All Cabin Lights cannot be dimmed or switched off or dim incorrectly
1. Possible Causes
_______________
- DIR-CIDS, 1 (101RH)
- ATTENDANT PANEL-FORWARD (120RH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-73-00-740-003 BITE Test of the Cabin Intercommunication Data System (CIDS) through the PTP AMM 23-73-12-000-001 Removal of the Forward Attendant Panel (FAP) frame 121RH AMM 23-73-12-400-001 Installation of the Forward Attendant Panel (FAP)
frame 121RH
AMM 23-73-34-000-001 Removal of the CIDS Director (101RH,102RH)
AMM 23-73-34-400-001 Installation of the CIDS Director (101RH,102RH)
AMM 33-21-00-710-001 Operational Test of the General Illumination
ASM 23-73/09
AWM 23-73-48
3. Fault Confirmation
__________________
A. Do the CIDS BITE test (Ref. AMM TASK 23-73-00-740-003).
B. Do the operational test of the general illumination (Ref. AMM TASK 33-21-00-710-001).
4. Fault Isolation
_______________
R
R A. If the test gives a maintenance message, do the trouble shooting R procedure related to the maintenance message.
B. If there is no CFDS message, but you cannot control any lights correctly:
- replace the DIR-CIDS, 1 (101RH) (Ref. AMM TASK 23-73-34-000-001) (Ref. AMM TASK 23-73-34-400-001).
(1) If the fault continues:
- replace the ATTENDANT PANEL-FORWARD (120RH) (Ref. AMM TASK 23-73-12-000-001) (Ref. AMM TASK 23-73-12-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-21-00∞∞∞∞∞∞∞∞∞∞Page 208
May 01/05 CES (2) If the fault continues:
- do a check of the wiring (Ref. ASM 23-73/09) and (Ref. AWM 23-73-48).
C. Do the test as given in the Para. 3.A .
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-21-00∞∞∞∞∞∞∞∞∞∞Page 209
Nov 01/04R
CES
TASK 33-21-00-810-806
Cabin Lights - All Cabin Lights Flicker
1. Possible Causes
_______________
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R AMM 24-21-00-730-040 System Test of the IDG Frequency (P/N 740119) AMM 24-21-51-000-040 Removal of the Integrated Drive Generator -IDG 1(2),(4000XU) AMM 24-21-51-400-040 Installation of the Integrated Drive Generator -IDG 1(2),(4000XU) AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from Engine 1(2) AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
AMM 71-00-00-710-003 Engine Automatic Start
AMM 71-00-00-710-025 Accel Check
AMM 71-00-00-710-028 Engine Shutdown
3. Fault Confirmation
__________________
A. Initial Maintenance Practices
(1) Make sure that there are no failure messages related to the generators or the Integrated Drive Generators (IDG) present.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 LIGHTS 灯光(38)