3. Fault Confirmation
__________________
A. Do the operational test Check Battery Capacity via MCDU (Ref. AMM TASK 33-51-00-710-011).
4. Fault Isolation
_______________
A. Do the operational test of the emergency lights via MCDU (Ref. AMM TASK 33-51-00-710-010).
B. If the operational test gives the maintenance message:
(1) NO TEST RESULT AVAIL/EPSU(12WL)EMER R:
- get access to EPSU 12WL (Ref. AMM TASK 33-51-38-000-001).
(a) Do a check and repair the wiring between: EPSU 12WL pin -I and DEU-B 300RH6 pin B25. EPSU 12WL pin -P and DEU-B 300RH6 pin B27. EPSU 12WL pin X and DEU-B 300RH6 pin B26 (Ref. ASM 33-51/02).
(b) If the fault continues:
- replace the EPSU (12WL) (Ref. AMM TASK 33-51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).
C. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page A262
Aug 01/05 CES
5. Close-up
________
A. Put the aircraft back to its initial configuration.
TASK 33-51-00-810-851
EPSU 13WL does not have a Test Result available
1. Possible Causes
_______________
- wiring
- EPSU (13WL)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 33-51-00-710-011 Check Battery Capacity via MCDU AMM 33-51-38-000-001 Removal of the Emergency Power-Supply Unit (EPSU) AMM 33-51-38-400-001 Installation of the Emergency Power-Supply Unit
(EPSU)
ASM 33-51/02
3. Fault Confirmation
__________________
A. Do the operational test Check Battery Capacity via MCDU (Ref. AMM TASK 33-51-00-710-011).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
B. If the operational test gives the maintenance message:
(1) NO TEST RESULT AVAIL/EPSU(13WL)AFT L:
- get access to EPSU 13WL (Ref. AMM TASK 33-51-38-000-001).
(a) Do a check and repair the wiring between: EPSU 13WL pin -I and DEU-B 300RH7 pin B29. EPSU 13WL pin -P and DEU-B 300RH7 pin B31. EPSU 13WL pin X and DEU-B 300RH6 pin B30 (Ref. ASM 33-51/02).
(b) If the fault continues:
- replace the EPSU (13WL) (Ref. AMM TASK 33-51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).
C. Do the test given in para. 3.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 301-399, 401-499, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page A264
Aug 01/05 CES
TASK 33-51-00-810-852
Failure of the Emergency Lights controlled by EPSU 11WL
1. Possible Causes
_______________
- CABIN EMERGENCY LIGHT (203WL)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 33-51-00-710-007 Operational Test of the Emergency Lighting in the
Cabin by 'LIGHT EMER' Pushbutton Switch AMM 33-51-00-710-010 Operational Test of the Emergency Lights via MCDU AMM 33-51-11-000-001 Removal of the Cabin Emergency Lights AMM 33-51-11-400-001 Installation of the Cabin Emergency Light ASM 33-51/02
3. Fault Confirmation
__________________
A. Do the operational test of the Emergency Lights via MCDU (Ref. AMM TASK 33-51-00-710-010).
4. Fault Isolation
_______________
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
B. If the operational test gives the maintenance message:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 LIGHTS 灯光(139)