R C. If the test gives the maintenance message EPSU INT LOAD EMER L, do the R operational test of the emergency cabin lights and signs (Ref. AMM TASK 33-51-00-710-004).
R NOTE : The time taken to do this test must not be more than 1 minute to
____ R prevent discharge of the emergency lighting batteries.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-158, ∞∞33-51-00∞∞∞∞∞∞∞∞∞∞Page 226
201-209, 229-299, May 01/05 CES
R (1) If one or more lamps of the LIGHTS-EMERGENCY, CABIN related to the
R POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
R - replace the lamp(s).
R (a) If the fault continues:
R - do a check for approx. 6 VDC at the related LIGHT-EMERGENCY,
R CABIN (Ref. ASM 33-51/02).
R 1 If there are approx. 6 VDC:_
R - replace the related LIGHT-EMERGENCY, CABIN (Ref. AMM TASK
R 33-51-11-000-001) and (Ref. AMM TASK 33-51-11-400-001).
R 2 If there are no 6 VDC:_
R - do a check and repair the wiring between the:
R POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/E or G and
R the related LIGHT-EMERGENCY, CABIN,
R related LIGHT-EMERGENCY, CABIN and GND (Ref. ASM 33-51/02).
R (2) If all LIGHTS-EMERGENCY, CABIN related to the POWER SUPPLY
R UNIT-EMERGENCY (11WL) do not come on:
R - replace the POWER SUPPLY UNIT-EMERGENCY (11WL) (Ref. AMM TASK 33-
R 51-38-000-001) and (Ref. AMM TASK 33-51-38-400-001).
R (3) If one or more lamps of the SIGNS-EXIT LOCATION or SIGNS-EXIT MARKING
R related to the POWER SUPPLY UNIT-EMERGENCY (11WL) do not come on:
R - replace the lamp(s).
R (a) If the fault continues:
R - do a check for approx. 6 VDC at the related SIGN-EXIT LOCATION
R or SIGN-EXIT MARKING (Ref. ASM 33-51/02).
R 1 If there are approx. 6 VDC:_
R - replace the related SIGN-EXIT LOCATION (Ref. AMM TASK 33-51-
R 17-000-001) and (Ref. AMM TASK 33-51-17-400-001) or
R SIGN-EXIT MARKING (Ref. AMM TASK 33-51-16-000-001) and (Ref.
R AMM TASK 33-51-16-400-001).
R 2 If there are no 6 VDC:_
R - do a check and repair the wiring between the:
R POWER SUPPLY UNIT-EMERGENCY (11WL) connector A/N or R and
R the related SIGN-EXIT LOCATION or SIGN-EXIT MARKING,