• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 22:45来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 33-13-00-991-006 Fig. 205
 33-13-00-991-003 Fig. 206

 3. Fault Confirmation
__________________
 A. Test Do the operational test of the instrument and panel integral lighting (Ref. AMM TASK 33-13-00-710-001). (Ref. Fig. 205/TASK 33-13-00-991-006)
 NOTE : Do this test for the glareshield integral lighting only.
____
 4. Fault Isolation
_______________
 A. If during the operational test when you move the glareshield
 potentiometer cursors (38LE).

 (1) One light of the related integrally lighted panel is inoperative:
 - remove the defective lamp or LED on the PLATE-INT LIGHTED IDENT (Ref. IPC 331308)

 - make sure that there is a voltage at the lamp socket.


 (a) If there is a voltage:
 - replace the defective lamp.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-13-00∞∞∞∞∞∞∞∞∞∞Page 211
 Feb 01/98 CES


 Instrument and Panel Integral Lighting
 Figure 205/TASK 33-13-00-991-006

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-13-00∞∞∞∞∞∞∞∞∞∞Page 212
 Feb 01/98 CES (b) If there is no voltage:


 - do a check and repair the wiring (Ref. ASM 33-13/03).
 (2) If the integral lighting of several instruments and/or panels is inoperative:
 - do a check of the lighting controller fuse related to the defective lighting circuit (Ref. ASM 33-13/03).
 (a) If the fuse is correct:
 - replace the CONTROLLER-LIGHTING (30LF) (Ref. AMM TASK 33-13-51-000-001) and (Ref. AMM TASK 33-13-51-400-001). (Ref. Fig. 206/TASK 33-13-00-991-003)
 1 If the fault continues:
_
 - do a check and repair the wiring related to the defective lighting circuit (Ref. ASM 33-13/03).
 (b) If the fuse is not correct:
 - replace the defective fuse.
 (3) If the related integral lighting panel does not operate correctly:
 - do a check of the circuit breaker (5LF) status.
 (a) If the circuit breaker is closed:
 - do a check for 115VAC at pin A/A of the lighting controller (30LF) (Ref. ASM 33-13/03).
 1 If there is 115VAC:
_
 - replace the CONTROLLER-LIGHTING (30LF) (Ref. AMM TASK 33-13-51-000-001) and (Ref. AMM TASK 33-13-51-400-001).
 a If the fault continues:
_
 - replace the LT-MAIN INSTRUMENT PNL, CENTER (38LE) (Ref. IPC 331201).
 b If the fault continues:
_
 - do a check and repair the wiring between the lighting controller (30LF) and the light of the center main instrument-panel (38LE).
 2 If there is no 115VAC:
_
 - do a check for a ground signal at pins A/C, B of the lighting controller (30LF) (Ref. ASM 33-13/03).
 a If there is no ground signal:
_
 - repair the defective wiring between the lighting controller (30LF) pin A/C or A/B and the ground terminal (Ref. ASM 33-13/03).
 b If there is a ground signal:
_
 - replace the C/B-LIGHTING/INST LT/GLARE/SHLD (5LF). . if the fault continues:
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-13-00∞∞∞∞∞∞∞∞∞∞Page 213
 Feb 01/98 CES


 Integral Lighting Controller Glareshield 30lf
 Figure 206/TASK 33-13-00-991-003

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞33-13-00∞∞∞∞∞∞∞∞∞∞Page 214
 Feb 01/98 CES - do a check and repair the wiring between the lighting controller (30LF) pin A/A and the circuit breaker (5LF) (Ref. ASM 33-13/03).


 (b) If the circuit breaker is open:
 - close the circuit breaker.
 1_ If the circuit breaker trips:
 - replace the CONTROLLER-LIGHTING (30LF) (Ref. AMM TASK 33-13-
51-000-001) and (Ref. AMM TASK 33-13-51-400-001).

 a If the fault continues:
_
 - do a check for a short to ground at the wiring between the lighting controller (30LF) pin A/A and the C/B (5LF) (Ref. ASM 33-13/03) . if there is a short to ground:
 - repair the related wiring. . if there is no short to ground:

 - replace the C/B-LIGHTING/INST LT/GLARE/SHLD (5LF).


 B. Do the test given in Para. 3.

 TASK 33-13-00-810-804


 Standby Compass Lighting Failure
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 LIGHTS 灯光(29)