3. Fault Confirmation
__________________
A. Do the DMU (1TV) fault monitoring test (Ref. AMM TASK 31-36-00-710-001). NOTE : Make sure that the circuit breakers 1TV, 5CC2, 14CC2 on the panel
____ 121VU and 5CC1, 14CC1 on the panel 49VU are closed during the test. _______________
4. Fault Isolation
R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
A. If the test gives the maintenance message:
- NO BSCU 1 DATA, or
- NO BSCU 2 DATA
(1) Do the operational test of the Normal Braking System (Ref. AMM TASK 32-42-00-710-001).
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
(2) If the fault continues:
- do a check and repair the wiring from the BSCU (10GG) to the DMU (1TV) (Ref. ASM 31-37/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 257
201-210, May 01/05 CES (3) If the fault continues:
- replace the DMU (1TV) (Ref. AMM TASK 31-36-34-000-001) and (Ref. AMM TASK 31-36-34-400-001).
**ON A/C 159-199, 210-210,
A. If the test gives the maintenance message:
- BSCU1 (10GG)/DMU(1TV) or
- BSCU2 (10GG)/DMU(1TV)
(1) Do the operational test of the Normal Braking System (Ref. AMM TASK 32-42-00-710-001).
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
(2) If the fault continues:
- do a check and repair the wiring from the BSCU (10GG) to the DMU (1TV) (Ref. ASM 31-37/01).
(3) If the fault continues:
- replace the DMU (1TV) (Ref. AMM TASK 31-36-34-000-001) and (Ref. AMM TASK 31-36-34-400-001).
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 151-199, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 258
201-210, May 01/05 CES
R **ON A/C 001-049, 051-099, 101-105, 159-199, 210-210,
TASK 31-36-00-810-892
DMU Battery (1TV)
1. Possible Causes
_______________
- DMU (1TV)
- Battery
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-36-00-710-001 Test of the DMU (1TV)
AMM 31-36-00-960-002 Replacement of the DMU Batteries
AMM 31-36-34-000-001 Removal of the Data Management Unit (DMU) (1TV)
AMM 31-36-34-400-001 Installation of the Data Management Unit (DMU) (1TV)
3. Fault Confirmation
__________________
A. Do the DMU (1TV) fault monitoring test (Ref. AMM TASK 31-36-00-710-001).
(1) If the Result Power Up Test Page gives these messages, replace the DMU (1TV) (Ref. AMM TASK 31-36-34-000-001) and (Ref. AMM TASK 31-36-34-400-001):
- EPROM I/O FAILURE (CPU1). . . . . . . . I . . .2
- SRAM FAILURE (CPU1). . . . . . . . . . .I . . .2
- FLASH PROM FAIL (CPU1). . . . . . . . . I . . .2
- ACQUI. BUS INTERFACE. . . . . . . . . . I . . .2
- DIAL. BUS INTERFACE. . . . . . . . . . .I . . .2
- EEPROM FAILURE (CPU1). . . . . . . . . .I . . .2
- INVALID OP SOFT. . . . . . . . . . . . .I . . .2
- CPU1/CPU2 SYNCHRO. . . . . . . . . . . .I . . .2
- EPROM FAILURE (CPU2). . . . . . . . . . I . . .2
- SRAM FAILURE (CPU2). . . . . . . . . . .I . . .2
- FLASH PROM FAIL (CPU2). . . . . . . . . I . . .2
- SAR MEMORY FAILURE. . . . . . . . . . . I . . .2
- DAR EMISSION FAILUR. . . . . . . . . . .I . . .2
- CPU1/CPU2 SYNC. FAILURE. . . . . . . . .I . . .2
- POWER SUPPLY ALARM. . . . . . . . . . . I . . .2
- INVALID OP. SOFTWARE. . . . . . . . . . I . . .3
- INVALID DATABASE. . . . . . . . . . . . I . . .3
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, 159-199, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 259
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(96)