(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
(2) If the fault continues:
- do a check and if necessary repair the wiring between the FCU (2CA) and the DMU/FDIU (FDIMU) (10TV) (Ref. ASM 31-37/01):
FCU Connector A/DD to FDIMU Connector AA/5A FCU Connector A/EE to FDIMU Connector AA/5B FCU Connector A/FF to FDIMU Connector AB/5A FCU Connector A/GG to FDIMU Connector AB/5B
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 211-299, 301-399, 401-499, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 284
Aug 01/05 CES (3) If the fault continues:
- replace the FDIMU (10TV) (Ref. AMM TASK 31-36-34-000-002) and (Ref. AMM TASK 31-36-34-400-002).
B. Do the test given in para. 3.
FDIMU receives no data from the GPWC (1WZ)
1. Possible Causes
_______________
- GPWC (1WZ)
- DMU/FDIU (FDIMU) (10TV)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-36-00-740-012 Test of the FDIMU (10TV)
AMM 31-36-34-000-002 Removal of the FDIU/DMU (FDIMU) (10TV)
AMM 31-36-34-400-002 Installation of the FDIU/DMU (FDIMU) (10TV)
AMM 34-48-00-710-001 Operational Test of GPWS Ground Self-test Function
ASM 31-37/01
3. Fault Confirmation
__________________
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) (Ref. AMM TASK 31-36-00-740-012).
NOTE : Make sure that the circuit breakers 5TV, 2WZ, 3WZ on the panel
____
121VU are closed during the test.
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
- GPWC(1WZ) / FDIMU(10TV)
(1) Do the operational test of the Ground Proximity Warning System (Ref. AMM TASK 34-48-00-710-001).
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
(2) If the fault continues:
- do a check and if necessary repair the wiring between the GPWC (1WZ) and the DMU/FDIU (FDIMU) (10TV) (Ref. ASM 31-37/01):
GPWC Connector AB/1C to FDIMU Connector AA/5C GPWC Connector AB/1D to FDIMU Connector AA/5D
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-149, 211-299, 301-399, 401-499, ∞∞31-36-00∞∞∞∞∞∞∞∞∞∞Page 286
Aug 01/05 CES (3) If the fault continues:
- replace the FDIMU (10TV) (Ref. AMM TASK 31-36-34-000-002) and (Ref. AMM TASK 31-36-34-400-002).
B. Do the test given in para. 3.
FDIMU receives no data from the CFDS
1. Possible Causes
_______________
- CFDIU (1TW)
- DMU/FDIU (FDIMU) (10TV)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-32-00-740-002 BITE Test of the Centralized Fault Display Interface
Unit (CFDIU)
AMM 31-36-00-740-012 Test of the FDIMU (10TV)
AMM 31-36-34-000-002 Removal of the FDIU/DMU (FDIMU) (10TV)
AMM 31-36-34-400-002 Installation of the FDIU/DMU (FDIMU) (10TV)
ASM 31-36/01
3. Fault Confirmation
__________________
A. Do the FDIMU (10TV) fault monitoring test (AIDS-part) (Ref. AMM TASK 31-36-00-740-012).
NOTE : Make sure that the circuit breakers 5TV, 2TW, 8TW on the panel
____
121VU are closed during the test.
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
- CFDIU (1TW) / FDIMU (10TV)
(1) Do the BITE test of the Central Fault Display Interface System (CFDIU) (Ref. AMM TASK 31-32-00-740-002).
(a) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
(2) If the fault continues:
- do a check and if necessary repair the wiring between the CFDIU (1TW) and the DMU/FDIU (FDIMU) (10TV) (Ref. ASM 31-36/01):
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 1(104)